Hayward Ecommand W/2Gva/Base/Aquaconne ECOMMAND-4-Installation-Manual-092419AR - Page 25

Aux1 Relay, Aux1 Interlock, Aux1 Freeze Protection, Aux1 Pump Speed, Valve3 Function

Page 25 highlights

Aux1 Relay This feature allows the user to select either "Standard" (default) or "Dimmer" type relay for the Aux1 output. The optional AQL-DIM dimmer kit must be installed if "Dimmer" is desired. When "Dimmer" is selected, and the Aux1 output is manually turned on, the "+" and "-" buttons adjust the level from 20% to 100% (default). The level is saved for the next time the aux1 output is turned from off to on. Aux1 Interlock If "Enabled", this feature will override the function (Manual On/Off, Countdown Timer, Timeclock), selected above and turn the aux1 off when: filter pump is off, first 3 minutes of filter pump operation (allows the pump to prime and get water flowing), when the pool/spa suction return valves are in any position other than "pool only", or for the first 3 minutes after solar turns on (allows air in the solar panels to be purged). Interlock is not available for solar, low speed filter pump, super chlorinate or dimmer. Aux1 Freeze Protection This function protects the pool, plumbing, and equipment against freeze damage. If Freeze Protection is enabled and the AIR temperature falls below the selected freeze temperature threshold, the ECOMMAND 4 will turn on the aux relay to circulate the water. IMPORTANT: this only enables operation of the AUX output during freeze--see the "Filter Pump Config." menu to enable freeze protection for the main circulation system. Aux1 Pump Speed This is the speed of the pump when the Aux1 output is on. The choices are the Settings Menu speed and a speed that is unique to the Aux1 output only. The default selection is in the "Settings Menu". This is the speed of the pump that has been selected in the Settings Menu for normal filter operation. If an alternate speed is desired when the Aux1 output is on, push "+" or "-" and select from "Lowest" to "Highest" in 5% increments. Valve3 Config. + to view/change Push to access Valve3 options Move to previous/next configuration menu Valve3 Function Solar Rotates between Timeclock (default), Solar, In-floor Cleaner, Filter, Lights, Aux1 and Aux2 Move to next menu item for all functions except solar and super chlorinate Valve3 Interlock Toggle between Enabled and Disabled (default) Valve3 Interlock Disabled Move to next menu item for all functions except super chlorinate Valve3 Freeze Toggle between Enabled and Disabled (default) Valve3 Freeze Disabled Move to previous/next configuration menu only if filter pump is set to variable and relay type is set to standard Valve3 Pump Spd Settings Menu Select between Settings Menu (default) and the desired pump speed Move to previous/next configuration menu Valve3 Function Timeclock (default) - the valve turns on/off at the times set for the valve3 timeclock in the Timers Menu (see Operations Manual). Solar - the valve operates when the filter pump is running, solar heat is available, and the water is less than the desired temperature setting. Solar heating must be enabled in the "Solar Config." menu for proper operation to occur. 24 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
24
Aux1 Relay
This feature allows the user to select either “Standard” (default) or “Dimmer” type relay
for the Aux1 output.
The optional AQL-DIM dimmer kit must be installed if “Dimmer” is
desired.
When “Dimmer” is selected, and the Aux1 output is manually turned on, the
“+” and “-” buttons adjust the level from 20% to 100% (default).
The level is saved for
the next time the aux1 output is turned from off to on.
Aux1 Interlock
If “Enabled”, this feature will override the function (Manual On/Off, Countdown Timer,
Timeclock), selected above and turn the aux1 off when:
filter pump is off, first 3
minutes of filter pump operation (allows the pump to prime and get water flowing),
when the pool/spa suction return valves are in any position other than “pool only”, or
for the first 3 minutes after solar turns on (allows air in the solar panels to be purged).
Interlock is not available for solar, low speed filter pump, super chlorinate or dimmer.
Aux1 Freeze Protection
This function protects the pool, plumbing, and equipment against freeze damage.
If
Freeze Protection is enabled and the AIR temperature falls below the selected freeze
temperature threshold, the ECOMMAND 4 will turn on the aux relay to circulate the wa-
ter.
IMPORTANT:
this only enables operation of the AUX output during freeze--see the
“Filter Pump Config.” menu to enable freeze protection for the main circulation system.
Aux1 Pump Speed
This is the speed of the pump when the Aux1 output is on.
The choices are the Set-
tings Menu speed and a speed that is unique to the Aux1 output only.
The default
selection is in the “Settings Menu”.
This is the speed of the pump that has been
selected in the Settings Menu for normal filter operation. If an alternate speed is desired
when the Aux1 output is on, push “+” or “-” and select from “Lowest” to “Highest” in
5% increments.
Valve3 Function
Timeclock (default)
– the valve turns on/off at the times set for the valve3 timeclock in
the Timers Menu (see Operations Manual).
Solar
– the valve operates when the filter pump is running, solar heat is available, and
the water is less than the desired temperature setting.
Solar heating must be enabled
in the “Solar Config.” menu for proper operation to occur.
Valve3 Pump Spd
Settings Menu
Select between Settings Menu (default) and the desired pump speed
only if filter pump is set to variable
and relay type is set to standard
Move to previous/next configuration menu
Valve3 Freeze
Disabled
Toggle between Enabled and Disabled (default) Valve3 Freeze
Move to previous/next configuration menu
for all functions except super chlorinate
Valve3 Config.
+ to view/change
Valve3 Function
Solar
Push to access Valve3 options
Rotates between
k
Timecloc
(default), Solar, In-floor Cleaner,
Filter, Lights, Aux1 and Aux2
Move to previous/next configuration menu
Move to next menu item
Valve3 Interlock
Disabled
Toggle between Enabled and Disabled (default) Valve3 Interlock
Move to next menu item
for all functions except solar and super chlorinate