diagRetry
View all HP Brocade 8/24c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 255 highlights
22 diagRetry diagRetry SYNOPSIS Sets or displays diagnostic retry mode. diagretry [mode | -show] DESCRIPTION Use this command to enable retry mode if the mode value is nonzero and to disable the retry mode if the mode value is 0. The mode value is saved in nonvolatile memory until you change the mode. Changes made by this command do not require a reboot to take effect. Retry mode modifies the behavior of the diagnostic test methods, power-on self-test (POST), and burn-in scripts. The exact behavior depends on the tests and scripts that are run. NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for details. OPERANDS This command has the following optional operands: mode Specify 1 to enable retry mode. Specify 0 to disable the feature. -show Displays the current mode setting. The --show option is equivalent to using the command without operands. EXAMPLES To view and modify the current retry mode value: switch:admin> diagretry -show Diagnostic Retry Mode is currently enabled. switch:admin> diagretry 0 Config update Succeeded Diagnostic Retry Mode is now disabled. switch:admin> diagretry 1 Config update Succeeded Diagnostic Retry Mode is now enabled. SEE ALSO None Fabric OS Command Reference 221 53-1001764-01