HP Envy 15-1000se HP ENVY 15 - Maintenance and Service Guide - Page 41
Packaging and transporting guidelines
View all HP Envy 15-1000se manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 41 highlights
Removal and replacement procedures The following table shows how humidity affects the electrostatic voltage levels generated by different activities. Ä CAUTION: A product can be degraded by as little as 700 V. Typical electrostatic voltage levels Event Walking across carpet Walking across vinyl floor Motions of bench worker Removing DIPS from plastic tube Removing DIPS from vinyl tray Removing DIPS from Styrofoam Removing bubble pack from PCB Packing PCBs in foam-lined box 10% 35,000 V 12,000 V 6,000 V 2,000 V 11,500 V 14,500 V 26,500 V 21,000 V Relative humidity 40% 55% 15,000 V 7,500 V 5,000 V 3,000 V 800 V 400 V 700 V 400 V 4,000 V 2,000 V 5,000 V 3,500 V 20,000 V 7,000 V 11,000 V 5,000 V Packaging and transporting guidelines Follow these grounding guidelines when packaging and transporting equipment: ■ To avoid hand contact, transport products in static-safe tubes, bags, or boxes. ■ Protect ESD-sensitive parts and assemblies with conductive or approved containers or packaging. ■ Keep ESD-sensitive parts in their containers until they arrive at static-free workstations. ■ Place items on a grounded surface before removing them from their containers. ■ Always be properly grounded when touching a component or assembly. ■ Store reusable ESD-sensitive parts from assemblies in protective packaging or nonconductive foam. ■ Use transporters and conveyors made of antistatic belts and roller bushings. Be sure that mechanized equipment used for moving materials is wired to ground, and that proper materials are selected to avoid static charging. When grounding is not possible, use an ionizer to dissipate electric charges. Maintenance and Service Guide 4-3