HP Latex 820 HP Scitex LX850 & LX820 Printer: Installation Guide - Page 34

Check resistances, Curing Module Configuration, WARNING

Page 34 highlights

Curing Module Configuration 1. Remove all the T10 screws securing the right cover of the curing module and remove the cover. TIP: The heating module cover you must remove is marked with orange tape. 2. There is a strap that does not allow you to remove the terminal block. Remove this strap, taking care that you replace it after making the configuration. 3. Remove the T15 screw securing the terminal block and pull it out for easy access. 4. To make the delta or star configuration, use the metal strips and configure them according to the table. Use an M7 socket wrench to secure them. WARNING! The curing module terminal block must use the same configuration as the drying module. Check resistances Check the resistance at the output of the static relay, as shown below, through the hole protecting the static relay. 30 Chapter 6 Configure the electrical system ENWW

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85

Curing Module Configuration
1.
Remove all the T10 screws securing the right cover of the curing module and remove the cover.
TIP:
The heating module cover you must remove is marked with orange tape.
2.
There is a strap that does not allow you to remove the terminal block. Remove this strap, taking
care that you replace it after making the configuration.
3.
Remove the T15 screw securing the terminal block and pull it out for easy access.
4.
To make the delta or star configuration, use the metal strips and configure them according to the
table. Use an M7 socket wrench to secure them.
WARNING!
The curing module terminal block must use the same configuration as the drying
module.
Check resistances
Check the resistance at the output of the static relay, as shown below, through the hole protecting the
static relay.
30
Chapter 6
Configure the electrical system
ENWW