HP ProLiant 6400R Compaq ProLiant 6400R Servers - Page 101
Message, Description, Recommended Action
View all HP ProLiant 6400R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 101 highlights
3-34 Compaq ProLiant 6400R Maintenance and Service Guide Table 3-18 ADU Diagnostic Messages continued Message Description Accelerator status: Obsolete data was flushed (written) to drives During reset initialization, obsolete data were found in cache. Obsolete data were written to the drives, but newer data may have been overwritten. Accelerator status: Permanently disabled Array accelerator board has been permanently disabled. It remains disabled until it is reinitialized using the Array Configuration Utility (ACU). Accelerator status: Possible data loss in cache Possible data loss detected during power-up because all batteries are below sufficient voltage level and no presence of identification signatures on the array accelerator board. Accelerator status: Temporarily disabled Array accelerator board has been temporarily disabled. Accelerator status: Unrecognized status A status returned from the array accelerator board that ADU does not recognize. Accelerator status: Valid data found at reset Valid data were found in posted write memory at reinitialization. Data will be flushed to disk. Not an error or data loss condition. Accelerator status: Warranty alert Catastrophic problem with array accelerator board. Refer to other messages on Diagnostics screen for exact meaning of this message. Adapter/NVRAM ID mismatch EISA nonvolatile RAM has an ID for a different controller from the one physically present in the slot. Array accelerator battery pack X not fully charged Battery is not fully charged. Array accelerator battery pack X below reference voltage (recharging) Board in use by expand operation Battery pack on array accelerator is below required voltage levels. Array accelerator memory is in use by Expand operation. Recommended Action If newer data were overwritten, you may need to restore newer data. Otherwise, normal operations should continue. Check the Disable Code field. Run ACU to reinitialize the array accelerator board. There is no way to determine if dirty or bad data were in the cache and are now lost. Check the Disable Code field. Obtain the latest version of ADU. No action required. Replace the array accelerator board. Run the System Configuration Utility. If 75 percent of batteries present are fully charged, array accelerator is fully operational. If less than 75 percent of batteries are fully charged, allow 36 hours to recharge them. Allow enough time for batteries to recharge (36 hours). If batteries have not recharged after 36 hours, replace the array accelerator board. Operate system without array accelerator board until Expand operation completes. continued