HP ProLiant 6400R Compaq ProLiant 6400R Servers - Page 86
Run the System Configuration
View all HP ProLiant 6400R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 86 highlights
Diagnostics and Troubleshooting 3-19 Table 3-2 POST Error Messages continued Error Code Audible Beeps 1790-Disk 0 None Configuration Error 1791-Disk 1 Error None 1792-Drive Array None Reports Valid Data Found in Array Accelerator. Data will automatically be written to drive array. 1793-Drive Array - None Array Accelerator Battery Depleted - Data Lost (Error message 1794 also displays.) 1794-Drive Array - None Array Accelerator Battery Charge Low. Array Accelerator is temporarily disabled. Array Accelerator will be re-enabled when battery reaches full charge. 1795-Drive Array - None Array Accelerator Configuration Error. Data does not correspond to this drive array. Array Accelerator is temporarily disabled. 1796-Drive Array - None Array Accelerator Not Responding. Array Accelerator is temporarily disabled. Probable Source of Problem Hard drive error or wrong drive type Hard drive error or wrong drive type While the system was in use, power was interrupted while data were in the array accelerator memory. Power was then restored within 8 to 10 days, and the data in the array accelerator were flushed to the drive array. Recommended Action Run the System Configuration Utility and Diagnostics and correct. Run the System Configuration Utility and Diagnostics and correct. No action necessary because no data were been lost. Perform orderly system shutdowns to avoid data remaining in the array accelerator. While the system was in use, power was interrupted while data were in the array accelerator memory. Array accelerator batteries failed. Power was not restored within 8 to 10 days. The data in the array accelerator were lost. The battery charge is below 75%. Posted writes are disabled. Perform orderly system shutdowns to avoid data remaining in the array accelerator. Replace the array accelerator board if batteries do not recharge within 36 power-on hours. While the system was in use, power was interrupted while data were in the array accelerator memory. The data stored in the array accelerator do not correspond to the drive array. Match the array accelerator to the correct drive array, or run the System Configuration Utility to clear the data in the array accelerator. Array accelerator is defective or has been removed. Check that the array accelerator is properly seated. Run the System Configuration Utility to reconfigure the Compaq IDA-2 without the array accelerator. continued