HP ProLiant 6400R Compaq ProLiant 6400R Servers - Page 162
I/O Fan Fan X failure
View all HP ProLiant 6400R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 162 highlights
Array Accelerator Read Error 3-20 Array Accelerator Write Error 3-20 Controller detects replacement drives 3-15 Drive Failure 3-16 Drive(s) Disabled due to Array Accelerator Data Loss 3-20 External Drive Subsystem Error 3-15 not Configured 3-17 Operating in Interim Recovery Mode 3-18 Recovery Needed 3-18 Reports Valid Data 3-19 resuming Automatic Data Recovery process 3-15 SCSI Port Termination Error 3-15 Drive Monitoring features are unobtainable 3-37 Drive Monitoring is NOT enabled 3-37 Drive Not Responding 3-18 Drive time-out occurred on physical drive bay X 3-37 Drive X indicates position Y 3-37 Duplicate write memory error 3-37 Error occurred reading RIS copy from SCSI Port X 3-37 Fan controller not responding 3-11 Fan failure detected 3-10 Fatal ROM Error 3-7 Fixed Disk 0 does not support DMA Mode 3-12 Fixed Disk does not support Block Mode 3-13 Fixed Disk failed Identify command 3-13 Fixed Disk failed Set Block Mode command 3-13 FYI, Drive (bay) X is non-Compaq supplied 3-37 I/O Fan (Fan X) failure detected 3-10, 3-11 I/O Fan controller not responding 3-11 I/O ROM Error 3-7 Identify controller data did not match NVRAM 3-38 Index 7 Identify logical drive data did not match NVRAM 3-38 Incorrect Drive Replaced 3-18 Insufficient adapter resources 3-38 Internal SCSI Jumper Board Not Installed 3-12 Invalid Memory Configuration 3-8 Invalid Memory Speed 3-8 Keyboard Controller Error 3-10 Keyboard Error 3-9 Keyboard or System Unit Error 3-10 Less than 75% batteries at sufficient voltage 3-38 Locked SCSI Bus Detected. 3-11 Log Reinitialized 3-8 Logical drive X failed due to cache error 3-38 Logical drive X status Failed 3-39 Interim Recovery 3-39 Loose Cable Detected 3-39 Needs Recover 3-39 Overheated 3-39 Overheating 3-39 Recovering 3-39 Wrong Drive Replaced 3-39 Loose cable detected logical drives may be marked FAILED 3-40 Loose cable detected, logical drives may be marked FAILED 3-40 Low System Battery 3-11 Memory Address Error 3-8 Memory Detection Failure 3-8 Memory Error 3-8 Memory Size Error 3-8 Mirror data miscompare 3-40 No configuration for accelerator board 3-40 Nonfunctioning Voltage Regulator Module 3-9 NVRAM configuration present, controller not detected 3-40 Parallel Port X Address Assignment Conflict 3-10 PCI slots powered down 3-11 Permanently disabled 3-34 Power Fault On Processor Bus X 3-9