HP ProLiant DL280 HP ProLiant Storage Server with Windows Storage Server 2003 - Page 10
system, installation, recovery, workaround, performed, device, process, deletes, stored, drives.
View all HP ProLiant DL280 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
Configuration This section provides additional information on configuring your storage server. Issue: Configuration An unknown PCI serial port device can be seen in Windows Device Manager Description On the ML310 G3 storage server, if the optional serial port is enabled, a PCI serial port can show up as an unknown device. Workaround Reboot the system, press F9 during boot to enter the RBSU, open the Advanced Options, choose the Erase Non-volatile Memory option, and confirm the erase. This sets the BIOS back to factory defaults. Issue: Replacement drive does not remirror data drive Description Windows may not allow a remirroring of data drives after replacing a drive for the DL100 G2 storage servers and StorageWorks NAS 1200s. When trying to perform a remirror of the data drives after replacing a failed drive, the Repair Volume selection in Disk Management cannot be selected (remains grayed out). Workaround Contact HP Support, return the drive, and request a new replacement drive; or perform a system installation and recovery to resynchronize the drives. WARNING! If a system installation and recovery workaround is performed, back up all data on the NAS device, as the process deletes all data stored on the drives. Issue: Hard drive monitor service fault Description The hdmonsvc.exe application on the DL100 G2 storage and DPS servers may fault and write a "faulting application" error message in the system event log. This service monitors the internal hard drive status and updates the status LEDs on the front of the server. Workaround This issue occurs because of a missing disk in Disk Manager. Resolve the missing disk problem, and restart the HDMonSvc service from the Service Management console. Issue: DL100 G2 server/driver fail message on reboot Description A server/driver fail message may be displayed on bootup of the DL100 G2 storage server. Workaround This can be caused by the HDMonSvc service not reporting status to the Service Control Manager. In this case it is an incorrect error. Check the event logs for other services that may be reporting a failed condition. Issue: Hardware RAID drive letter setup on DL100 G2 storage server Description The DON'T ERASE partition may have both a drive letter and a mount point configured. This is not by design and may cause the data disk to not be formatted or have a drive letter. Workaround Manually remove the drive letter from the DON'T ERASE disk using Disk Manager. Format, add a drive letter, and label the data disk, if required. Issue: A blue screen occurs on the DL100 G2 if rebooted during resynchronization of the storage volume 10