procedures, diagnostic tools, specifications for hardware components, and software for the HP ProLiant SL4500 Series chassis. This guide is for an experienced service technician. HP assumes you are qualified in the servicing of computer equipment, trained in recognizing hazards in products, and are - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 2
to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 3
repair ...5 Parts only warranty service ...5 Illustrated parts catalog electrostatic discharge ...35 Symbols on equipment ...35 Server warnings and cautions ...36 System fans ...36 Troubleshooting ...61 Troubleshooting resources ...61 Diagnostic tools ...62 HP ROM-Based Setup Utility ...62 HP - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 4
Integrated Management Log ...62 HP Insight Remote Support software ...63 Component identification ...64 Front panel components ...64 Drive display LEDs ...65 Node front panel LEDs and buttons 67 Rear panel components...67 I/O module - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 5
period HP (or HP service providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship is required, you can call the HP Technical Support Center and a technician will help you over the telephone. HP specifies in the materials shipped with a - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 6
pièce défectueuse, HP se réserve le droit de vous facturer les coûts de remplacement. Dans le cas d'une pièce CSR, HP supporte l'ensemble des frais le site Web HP (http://www.hp.com/go/selfrepair). Service de garantie "pièces seules" Votre garantie limitée HP peut inclure un service de garantie "pi - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 7
Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen verfügbar. Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen lassen. Den - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 8
CSR-Verfahren zwingend vorgegeben. Wenn Sie den Austausch dieser Teile von HP vornehmen lassen, werden Ihnen die Anfahrt- und Arbeitskosten für diesen Service berechnet. Reparaciones del propio cliente Los productos de HP incluyen muchos componentes que el propio usuario puede reemplazar (Customer - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 9
minimum beperkt kan blijven en de flexibiliteit in het vervangen van defecte onderdelen groter is. Deze onderdelen worden CSR-onderdelen (Customer Self Repair) genoemd. Als HP (of een HP Service Partner) bij de diagnose vaststelt dat de reparatie kan worden uitgevoerd met een CSR-onderdeel, verzendt - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 10
voor meer informatie over het Customer Self Repair programma van HP. Informatie over Service Partners vindt u op de HP website (http://www.hp.com/go/selfrepair). Garantieservice "Parts Only" Het is mogelijk dat de HP garantie alleen de garantieservice "Parts Only" omvat. Volgens de bepalingen - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 11
No caso desse serviço, a substituição de peças CSR é obrigatória. Se desejar que a HP substitua essas peças, serão cobradas as despesas de transporte e mão-de-obra do serviço. Customer self repair 11 - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 12
Customer self repair 12 - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 13
Customer self repair 13 - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 14
Customer self repair 14 - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 15
Illustrated parts catalog Mechanical components Mechanical components (1 node chassis) Item Description 1 HP ProLiant SL4500 Series chassis 2 Drive blank 3 Access panel 4 Midplane cover 5 Fan louver 6 Midplane baffle 7 I/O blank 8 Power supply blank 9 Rack rail adapter kit* 10 - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 16
optional ist. Diese Teile sind auch für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen. 3No: Kein-Einige Teile sind nicht - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 17
-Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou não a cobrança de taxa adicional, dependendo do tipo de serviço de garantia destinado ao produto. 3No: Nenhuma-Algumas pe - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 18
Description Spare part number Customer self repair (on page 5) 1 HP ProLiant SL4500 Series chassis 2 Drive blank 3 Access panel - 667279-001 mandatory. If you request HP to replace these parts, you will be charged for the travel and labor costs of this service. 2Optional-Parts for which - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 19
optional ist. Diese Teile sind auch für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen. 3No: Kein-Einige Teile sind nicht - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 20
Illustrated parts catalog 20 - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 21
System components System components (1 node chassis) Item Description 14 Management module 15 Power supplies a) 1200 W, Platinum Plus, 94% b) 750 W, Platinum Plus, 94%* c) 750 W, 92%* 16 System fan 17 I/O module (See I/O module components (on page 27)) 18 Midplane 19 Drive backplane 20 Drives, LFF - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 22
optional ist. Diese Teile sind auch für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen. 3No: Kein-Einige Teile sind nicht - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 23
ser reparados por el usuario. Para que el usuario haga valer su garantía, HP pone como condición que un proveedor de servicios autorizado realice la sustitución de met de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden vervangen. Deze onderdelen worden in de ge - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 24
System components (2 node chassis) Item Description 14 Management module 15 Power supplies a) 1200 W, Platinum Plus, 94% b) 750 W, Platinum Plus, 94%* c) 750 W, 92%* 16 System fan 17 I/O module (See I/O module components (on page 27)) 18 Midplane 19 Drive backplane 20 Drives, LFF a) 450-GB 6G SAS - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 25
optional ist. Diese Teile sind auch für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen. 3No: Kein-Einige Teile sind nicht - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 26
ser reparados por el usuario. Para que el usuario haga valer su garantía, HP pone como condición que un proveedor de servicios autorizado realice la sustitución de met de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden vervangen. Deze onderdelen worden in de ge - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 27
P420i mezzanine controller 2 1Gb I/O module assembly 3 10Gb I/O module assembly 4 Server storage mezzanine to PCIe board 5 1-Gb Ethernet adapter, 4-port, 331T* 6 If you request HP to replace these parts, you will be charged for the travel and labor costs of this service. 2Optional-Parts for - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 28
optional ist. Diese Teile sind auch für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen. 3No: Kein-Einige Teile sind nicht - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 29
Illustrated parts catalog 29 - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 30
HP Insight Diagnostics software ("HP Insight Diagnostics" on page 62) Preparation procedures To access some components and perform certain service node for any upgrade or maintenance procedures, perform a backup of critical server data and programs. IMPORTANT: When the node is in standby mode, - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 31
Observe local occupational health and safety requirements and guidelines for manual material handling. • Remove all installed components from the assist with aligning the chassis with the rails while the other two people support the weight of the chassis. To remove the chassis: 1. Power down - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 32
the chassis on a flat surface. Remove a node from the chassis 1. Power down the node (on page 30). CAUTION: To avoid damage to the node, always support the bottom of the node when removing it from the chassis. 2. Remove the node from the chassis: a. Press the release button. Removal and replacement - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 33
b. Lower the handle. c. Remove the node. CAUTION: To avoid damage to the device, do not use the removal handle to carry it. 3. Place the node on a flat, level surface. Disconnect the cable management arm Before removing the chassis from the rack, you must first remove the cable management arm. - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 34
on top of the chassis. 2. Slide the access panel toward the front of the chassis. The access panel locks into position. Safety considerations Before performing service procedures, review all the safety information. Removal and replacement procedures 34 - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 35
of hazardous energy circuits or electric shock hazards. Refer all servicing to qualified personnel. WARNING: To reduce the risk of injury , observe local occupational health and safety requirements and guidelines for manual material handling. These symbols, on power supplies or systems, indicate - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 36
on or pinched by items placed against it. Pay particular attention to the plug, electrical outlet, and the point where the cord extends from the server. WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 37
: • Verify the status of the power supply to be replaced by reviewing rear panel LEDs and buttons. • Be sure that your configuration can support your actions. If the proper redundancy is not in place, power down the nodes before beginning this procedure. To remove the component: 1. Disconnect - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 38
2. Loosen the screw securing the management module to the chassis. 3. Remove the management module. To replace the component, reverse the removal procedure. I/O module To remove the component: 1. Power down the nodes ("Power down the node" on page 30). 2. Disconnect any cables connected to the I/O - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 39
3. Remove the I/O module. To replace the component, reverse the removal procedure. Expansion board To remove the component: 1. Power down the nodes ("Power down the node" on page 30). 2. Disconnect any cables connected to the I/O module. 3. Remove the I/O module ("I/O module" on page 38). 4. Remove - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 40
6. Remove the expansion board. To replace the component, reverse the removal procedure. Smart Array controller 1. Power down the nodes ("Power down the node" on page 30). 2. Disconnect any cables connected to the I/O module. 3. Remove the I/O module ("I/O module" on page 38). 4. Remove the I/O - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 41
5. If installed, remove the low profile option card. 6. Remove the expansion board. Removal and replacement procedures 41 - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 42
and cache battery. To replace the component, reverse the removal procedure. Drive blank CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank. Removal and replacement procedures 42 - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 43
Remove the drive blank. To replace the component, slide the component into the bay until it clicks. Drives To remove the component: 1. Determine the status of the drive from the drive LED definitions ("Drive display LEDs" on page 65). 2. Back up all data on the drive. 3. Remove the access panel (on - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 44
populated with either a component or a blank. To install the component: 1. Prepare the drive. IMPORTANT: The 1 node chassis supports up to 30 drives per drive backplane. The 2 node chassis supports up to 25 drives per drive backplane. Always populate drive bays from the rear to the front starting - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 45
IMPORTANT: Label the drives before removing them. The drives must be returned to their original locations. 2. Remove all drives in that segment ("Drives" on page 43). 3. Release the drive backplane. o 1 node o 2 node 4. Remove the drive backplane. Removal and replacement procedures 45 - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 46
o 1 node o 2 node To replace the component, reverse the removal procedure. Removing the fan cable To remove the component: 1. Power down the nodes ("Power down the node" on page 30). 2. Disconnect the cable management arm (on page 33). 3. Disconnect all cables from the rear of the chassis. 4. To - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 47
c. I/O modules ("I/O module" on page 38) d. Management module (on page 37) e. Drives (on page 43) 5. Place the chassis on a flat, level surface. 6. Disconnect the fan cable from each end of the midplane. 7. Disconnect each fan cable from the five fan connector ear pins. o 1 node chassis o 2 node - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 48
Removing the fan connector ear pin To remove the component: 1. Power down the nodes ("Power down the node" on page 30). 2. Disconnect the cable management arm. 3. Disconnect all cables from the rear of the chassis. 4. To reduce the weight of the chassis, remove the following components: a. Power - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 49
. To replace the component, reverse the removal procedure. Midplane assembly Midplane assembly (1 node chassis) To remove the component: IMPORTANT: All components must be removed to service the midplane assembly. 1. Power down the node (on page 30). Removal and replacement procedures 49 - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 50
2. Disconnect the cable management arm (on page 33). 3. Disconnect all cables from the rear of the chassis. 4. Remove the following components: a. Power supplies (on page 37) b. System fans (on page 36) c. I/O module (on page 38) d. Management module (on page 37) e. Drives (on page 43) f. Node (" - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 51
7. Remove the midplane cover. 8. Loosen the screws securing the midplane assembly to the chassis, and then lift it up to access the cables. Removal and replacement procedures 51 - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 52
9. Disconnect the cables from the midplane assembly. 10. Remove the midplane assembly. Removal and replacement procedures 52 - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 53
removal procedure. Be sure to align the midplane using the guides provided. When replacing the midplane cover, tilt it in (2 node chassis) To remove the component: IMPORTANT: All components must be removed to service the midplane assembly. 1. Power down the nodes ("Power down the node" on page - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 54
g. Drive backplanes ("Drive backplane" on page 44) 5. Place the chassis on a flat, level surface. 6. Use the Allen wrench to loosen the captive screws securing the midplane cover to the chassis. Removal and replacement procedures 54 - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 55
7. Remove the midplane cover. 8. Loosen the screws securing the midplane assembly to the chassis, and then lift it up to access the cables. Removal and replacement procedures 55 - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 56
9. Disconnect the cables from the midplane assembly. 10. Remove the midplane assembly. Removal and replacement procedures 56 - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 57
To replace the component, reverse the removal procedure. Be sure to align the midplane using the guides provided. When replacing the midplane cover, tilt it in toward the front of the chassis, and then down to align the screw holes. Midplane baffle - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 58
and safety requirements and guidelines for manual material handling. • Remove all installed or damage to the equipment, you must adequately support the chassis during installation and removal. WARNING: WARNING: Only authorized technicians trained by HP should attempt to replace this component. - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 59
2. Remove the rack rails. Removal and replacement procedures 59 - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 60
3. On the front of the rack, remove the two screws from each of the mounting brackets, and then remove the brackets. 4. Remove the four flathead screws, marked number 2, that secure the adapter rails to the rack, and then remove the adapter rails. To replace the component, reverse the removal - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 61
) • Simplified Chinese (http://www.hp.com/support/ProLiant_TSG_v1_sc) The HP ProLiant Gen8 Troubleshooting Guide, Volume II: Error Messages provides a list of error messages and information to assist with interpreting and resolving error messages on ProLiant servers and server blades. To view the - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 62
www.hp.com/support/rbsu). HP Insight Diagnostics HP Insight Diagnostics is a proactive node management tool, available in both offline and online versions, that provides diagnostics and troubleshooting capabilities to assist IT administrators who verify node installations, troubleshoot problems, and - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 63
to your IT environment through HP Insight Online, and is also the recommended version for HP Proactive Care Service. • HP Insight Remote Support Advanced supports medium-sized to large environments with up to 3,500 devices. It can be installed on a Windows ProLiant hosting device or a Windows ESXi - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 64
Component identification Front panel components • 1 node chassis Item 1 2 3 4 5 6 7 8 9 10 11 Description Node drives LFF drive health LED LFF drive UID Drives controlled by the array controller a. Port 1i b. Port 2i Drive display boards Node VGA connector Node USB connectors Node Power On/Standby - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 65
• 2 node chassis Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Description Node 1 Node drives LFF drive health LED LFF drive UID Drives controlled by node 1 P420i array controller Node 2 Drives controlled by node 2 P420i array controller Drive display boards Node VGA connector Node USB connectors Node - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 66
drive is selected. Drive health LEDs LED behavior Off Green Amber Definition System is off. Storage system health is good. System requires service or a fault is detected. Check drives, drive backplane, RAID controller, and system fans. UID LEDs LED behavior Off Blue flashing Definition Normal - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 67
Node front panel LEDs and buttons Item 1 2 3 4 Description UID LED button Node release button System Health LED Power On/Standby button and system power LED Status Blue = Activated Flashing blue = System is being remotely managed or firmware update is in progress. Off = Deactivated - Green = - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 68
Item 1 2 3 4 Description System fans I/O module Management module Power supplies • 2 node chassis Item 1 2 3 4 5 Description System fans I/O module for node 1 Management module Power supplies I/O module for node 2 I/O module connectors and LEDs • 1 Gb I/O module Component identification 68 - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 69
Item 1 2 3 4 5 Description Activity LED 1Gb connectors I/O module health LED Serial connector Link LED • 10 Gb I/O module Item 1 2 3 4 5 6 7 8 9 Description 1 Gb connectors I/O module health LED QSFP 10 Gb Ethernet or 40Gb IB connector, depending on configuration SFP+ 10Gb Ethernet connector - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 70
Description Status 10Gb/40Gb link LED Green = Network link Off = No network link 10Gb/40Gb activity Flashing amber = Network activity LED Off = No network activity Management module connectors and LEDs Item 1 2 3 4 5 Description UID LED Health LED Description RCM connector (SL-APM) - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 71
Device bay numbering Power supply LED Power LED Off Green Status • No AC power to power supply units. Check the AC power cord. • AC is present. Standby output is on; output is disabled. • Power supply failure (includes overvoltage and overtemperature) AC is present and main 12 V output is enabled - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 72
LED color Off Solid amber System fan status The fan is working or power is off. The fan module has failed. Component identification 72 - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 73
kg (95.00 lb) Hot-plug power supply calculations For hot-plug power supply specifications and calculators to determine electrical and heat loading for the server, refer to the HP Enterprise Configurator website (http://h30099.www3 - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 74
Acronyms and abbreviations CSR Customer Self Repair MDL midline MLC multilevel cell SL-APM HP ProLiant SL Advanced Power Manager Acronyms and abbreviations 74 - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 75
documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (mailto:[email protected]). Include the document title and part number, version number, or the URL when submitting your feedback. Documentation feedback 75 - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 76
64 C cable management arm 33 cautions 36 chassis, remove from rack 31 chassis, removing server 32 components 15, 30, 64 components, identification 15, 18, 21, 24, 27, 64, 67, 71 connectors 64 D diagnosing problems 61 diagnostic tools 62 diagnostics utility 62 drive backplane 44 drive blank 42 drive - HP ProLiant SL4545 | HP ProLiant SL4500 Series Chassis Maintenance and Service G - Page 77
-Based Setup Utility (RBSU) 62 S safety considerations 34 safety information 34 server, installation 32 Smart Array controller 40 specifications 73 static electricity 35 symbols on equipment 35 system fans 36 T troubleshooting 61 U UID LED 64 USB connectors 64 utilities 62 utilities, deployment 62
HP ProLiant SL4500 Series Chassis
Maintenance and Service Guide
Abstract
This guide describes identification and maintenance procedures, diagnostic tools, specifications for hardware components, and software for the HP
ProLiant SL4500 Series chassis. This guide is for an experienced service technician. HP assumes you are qualified in the servicing of computer
equipment, trained in recognizing hazards in products, and are familiar with weight and stability precautions.
Part Number: 683984-002
December 2012
Edition: 2