HP R1500 HP UPS R5000 User Guide - Page 33

Verifying the REPO port connection

Page 33 highlights

Main menu - Event Log Measurements - - - - Control - - - - Settings - - - - - - - - - - - Identification Submenu Battery status - Output Output Output Input Battery Go to Bypass mode Battery Test Display information or menu function Battery Charging/Floating/Resting, Charge Level, ERM Number, and Runtime Displays events and alarms Output watts and VA Output amps and power factor Output voltage and frequency Input voltage and frequency Battery voltage and percent charge Transfers the UPS system to internal Bypass mode When this command is active, the option changes to Go to Normal mode. Schedules a battery test Reset error state Reset alarms Load segments Turns load segments on or off Restore factory settings Resets the UPS back to factory settings Change language Changes language settings. The default is English. User Password Enables or disables password. Default: Disable. If Enable is selected, the password is USER. The password cannot be changed. Set date and time Sets date and time Control commands from serial Enables or disables serial port control port commands. Default: Enabled Output voltage Sets output voltage Auto start delay Selects load segment and delay time in seconds Automatic on battery shutdown Selects load segment and delay time in seconds On battery notice delay Sets delay time in seconds Site wiring fault alarm Enables or disables site wiring fault alarm. The default is Disabled Battery low alarm Sets battery low alarm. Default: 3 minutes. Automatic battery test Enables or disables battery test. Default: Disabled LCD contrast Change LCD contrast. Default: +0 - UPS Type / Part Number / Serial Number / NMC Firmware / Comm Firmware / UPS Firmware Verifying the REPO port connection NOTE: While testing, operate connected equipment in a safe test mode so the effects do not disrupt critical operations. After connecting the REPO port (on page 21): UPS operations 33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

UPS operations 33
Main menu
Submenu
Display information or menu function
Battery status
Battery Charging/Floating/Resting, Charge
Level, ERM Number, and Runtime
Event Log
Displays events and alarms
Measurements
Output
Output watts and VA
Output
Output amps and power factor
Output
Output voltage and frequency
Input
Input voltage and frequency
Battery
Battery voltage and percent charge
Control
Go to Bypass mode
Transfers the UPS system to internal Bypass
mode
When this command is active, the option
changes to Go to Normal mode.
Battery Test
Schedules a battery test
Reset error state
Reset alarms
Load segments
Turns load segments on or off
Restore factory settings
Resets the UPS back to factory settings
Settings
Change language
Changes language settings. The default is
English.
User Password
Enables or disables password. Default: Disable.
If Enable is selected, the password is USER. The
password cannot be changed.
Set date and time
Sets date and time
Control commands from serial
port
Enables or disables serial port control
commands. Default: Enabled
Output voltage
Sets output voltage
Auto start delay
Selects load segment and delay time in seconds
Automatic on battery shutdown Selects load segment and delay time in seconds
On battery notice delay
Sets delay time in seconds
Site wiring fault alarm
Enables or disables site wiring fault alarm. The
default is Disabled
Battery low alarm
Sets battery low alarm. Default: 3 minutes.
Automatic battery test
Enables or disables battery test. Default:
Disabled
LCD contrast
Change LCD contrast. Default: +0
Identification
UPS Type / Part Number / Serial Number /
NMC Firmware / Comm Firmware / UPS
Firmware
Verifying the REPO port connection
NOTE:
While testing, operate connected equipment in a safe test mode so the effects do not
disrupt critical operations.
After connecting the REPO port (on page
21
):