HP R1500 HP UPS R5000 User Guide - Page 45

Alarm number Alarm name, Alarm description, Alarm type, UPS Control Power

Page 45 highlights

Alarm number Alarm name 59 Utility Not Present 68 Battery DC Over Voltage 94 To Bypass Command 95 From Bypass Command 143 On Manual Bypass 149 Service Battery 159 Output Overload Level 2 162 Output Overload Level 3 168 UPS On Battery 169 UPS On Bypass 170 UPS Off 172 UPS On Command 173 UPS Off Command 174 Battery Shutdown 181 UPS Control Power ON 191 Battery Test Failed 194 Site Wiring Problem 199 Battery Disconnected 237 1600 1601 1602 1603 1999 UPS System Normal ABM State Charging ABM State Floating ABM State Resting ABM State OFF Clock set done Alarm description Alarm type The utility level has fallen below the Utility Not Present Notice threshold. Battery voltage levels have exceeded the maximum Alarm allowable limits. A request to transfer to Manual Bypass Mode Event received from software. A request to transfer to Operate Mode is received Event from software. The UPS is manually commanded to switch to bypass Notice and will remain in bypass until commanded out of bypass. A faulted battery string is detected, and the battery Alarm charger has been disabled until it is replaced. Load levels are greater than a level 2 Overload Alarm condition and less than a level 3 Overload condition. Load levels are greater than a level 3 threshold. Alarm The UPS is operating from batteries. Notice The UPS is operating from bypass. Notice The UPS is in Standby mode or Fault mode. Event Indicates a manually requested transition from Event Standby to Operate. This event is not triggered for auto restarts. A UPS OFF command was received from remote S/W Event and causes the UPS to open up all output relays and shed the load. The UPS has shut down due to running on battery for Alarm a long enough time to exhaust the battery capacity. The UPS is powered up. Event A weak battery string is detected during the battery Notice test. The difference between ground and neutral voltage is Alarm less than 30 V. Battery voltage is lower than the batteries Alarm disconnected level defined for this UPS. If ERMs are attached, this alarm does not trigger unless the ERMs are also disconnected, since they are paralleled with the battery bus. The UPS has started or returned to its normal Event operating mode of operation and no alarms are active. The status of ABM charge mode is constant current Event charging. The status of ABM charge mode is floating. Event The status of ABM charge mode is resting. Event The status of ABM charge mode is OFF or disabled. Event The UPS real time clock setting has been adjusted. Event Troubleshooting 45

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

Troubleshooting 45
Alarm number Alarm name
Alarm description
Alarm type
59
Utility Not Present
The utility level has fallen below the Utility Not Present
threshold.
Notice
68
Battery DC Over Voltage
Battery voltage levels have exceeded the maximum
allowable limits.
Alarm
94
To Bypass Command
A request to transfer to Manual Bypass Mode
received from software.
Event
95
From Bypass Command
A request to transfer to Operate Mode is received
from software.
Event
143
On Manual Bypass
The UPS is manually commanded to switch to bypass
and will remain in bypass until commanded out of
bypass.
Notice
149
Service Battery
A faulted battery string is detected, and the battery
charger has been disabled until it is replaced.
Alarm
159
Output Overload Level 2
Load levels are greater than a level 2 Overload
condition and less than a level 3 Overload condition.
Alarm
162
Output Overload Level 3
Load levels are greater than a level 3 threshold.
Alarm
168
UPS On Battery
The UPS is operating from batteries.
Notice
169
UPS On Bypass
The UPS is operating from bypass.
Notice
170
UPS Off
The UPS is in Standby mode or Fault mode.
Event
172
UPS On Command
Indicates a manually requested transition from
Standby to Operate. This event is not triggered for
auto restarts.
Event
173
UPS Off Command
A UPS OFF command was received from remote S/W
and causes the UPS to open up all output relays and
shed the load.
Event
174
Battery Shutdown
The UPS has shut down due to running on battery for
a long enough time to exhaust the battery capacity.
Alarm
181
UPS Control Power ON
The UPS is powered up.
Event
191
Battery Test Failed
A weak battery string is detected during the battery
test.
Notice
194
Site Wiring Problem
The difference between ground and neutral voltage is
less than 30 V.
Alarm
199
Battery Disconnected
Battery voltage is lower than the batteries
disconnected level defined for this UPS. If ERMs are
attached, this alarm does not trigger unless the ERMs
are also disconnected, since they are paralleled with
the battery bus.
Alarm
237
UPS System Normal
The UPS has started or returned to its normal
operating mode of operation and no alarms are
active.
Event
1600
ABM State Charging
The status of ABM charge mode is constant current
charging.
Event
1601
ABM State Floating
The status of ABM charge mode is floating.
Event
1602
ABM State Resting
The status of ABM charge mode is resting.
Event
1603
ABM State OFF
The status of ABM charge mode is OFF or disabled.
Event
1999
Clock set done
The UPS real time clock setting has been adjusted.
Event