HP R1500 HP UPS R5000 User Guide - Page 45
Alarm number Alarm name, Alarm description, Alarm type, UPS Control Power
View all HP R1500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
Alarm number Alarm name 59 Utility Not Present 68 Battery DC Over Voltage 94 To Bypass Command 95 From Bypass Command 143 On Manual Bypass 149 Service Battery 159 Output Overload Level 2 162 Output Overload Level 3 168 UPS On Battery 169 UPS On Bypass 170 UPS Off 172 UPS On Command 173 UPS Off Command 174 Battery Shutdown 181 UPS Control Power ON 191 Battery Test Failed 194 Site Wiring Problem 199 Battery Disconnected 237 1600 1601 1602 1603 1999 UPS System Normal ABM State Charging ABM State Floating ABM State Resting ABM State OFF Clock set done Alarm description Alarm type The utility level has fallen below the Utility Not Present Notice threshold. Battery voltage levels have exceeded the maximum Alarm allowable limits. A request to transfer to Manual Bypass Mode Event received from software. A request to transfer to Operate Mode is received Event from software. The UPS is manually commanded to switch to bypass Notice and will remain in bypass until commanded out of bypass. A faulted battery string is detected, and the battery Alarm charger has been disabled until it is replaced. Load levels are greater than a level 2 Overload Alarm condition and less than a level 3 Overload condition. Load levels are greater than a level 3 threshold. Alarm The UPS is operating from batteries. Notice The UPS is operating from bypass. Notice The UPS is in Standby mode or Fault mode. Event Indicates a manually requested transition from Event Standby to Operate. This event is not triggered for auto restarts. A UPS OFF command was received from remote S/W Event and causes the UPS to open up all output relays and shed the load. The UPS has shut down due to running on battery for Alarm a long enough time to exhaust the battery capacity. The UPS is powered up. Event A weak battery string is detected during the battery Notice test. The difference between ground and neutral voltage is Alarm less than 30 V. Battery voltage is lower than the batteries Alarm disconnected level defined for this UPS. If ERMs are attached, this alarm does not trigger unless the ERMs are also disconnected, since they are paralleled with the battery bus. The UPS has started or returned to its normal Event operating mode of operation and no alarms are active. The status of ABM charge mode is constant current Event charging. The status of ABM charge mode is floating. Event The status of ABM charge mode is resting. Event The status of ABM charge mode is OFF or disabled. Event The UPS real time clock setting has been adjusted. Event Troubleshooting 45