PCI I/O Card Installation, IMPORTANT

Page 56 highlights

PCI I/O Card Installation HP 9000 rp8420 servers implement manual retention latch (MRL) hardware for use in online add or replacement (OLAR) operations. If an MRL is left open while the server is booting, HP-UX can incorrectly cache PCI slot power status causing OLAR operations to fail. To prevent this situation, ensure all the MRLs are closed before booting the server. If OLAR reports that a slot is present and powered off, but no OLAR operations to turn power on to that slot have succeeded even after the MRL is closed, the MRL may have been left open during boot. To clear this condition, close the MRL for the PCI slot then power off the PCI slot using the rad -o command. This will allow future OLAR operations to succeed on this PCI slot. IMPORTANT: PCI I/O card installation procedures should be downloaded from the http://docs.hp.com Web site. Background information and procedures for adding a new PCI I/O card using online addition are found in the Interface Card OL* Support Guide. Prerequisites for Adding a PCI I/O Card Using the Attention Button The prerequisites for this procedure are: • Drivers for the card have already been installed. • There are no drivers associated with the slot. • The green power LED is steady OFF. Should the empty slot be in the ON state use the olrad command or the pdweb tool to power the slot OFF. • The yellow attention LED is steady OFF or is blinking if a user has requested the slot location. • Refer to the host bus adapter (HBA) documentation for details on card installation. • Run the olrad -q command to determine the status of all the PCI I/O slots. • Obtain a copy of the interface card guide for instructions on preparing the operating system for the online addition of the PCI I/O card before attempting to insert a PCI I/O card into the PCI-X card cage assembly backplane slot. CAUTION: Observe all ESD safety precautions before attempting this procedure. Failure to follow ESD safety precautions could result in damage to the server. This procedure describes how to perform an online addition of a PCI card using the attention button for cards whose drivers support OLAR. The attention button is also referred to as the doorbell. 1. Remove the top cover. 2. Remove the PCI bulkhead filler panel. 3. Flip the PCI manual release latch for the card slot to the open position. Refer to Figure 3-2. 4. Install the new PCI card in the slot. NOTE: A slow, firm pressure is needed to properly seat the card into the backplane. 5. Flip the PCI manual release latch for the card slot to the closed position. CAUTION: Working out of sequence or not completing the actions within each step could cause the system to crash. Do not press the attention button until the latch is locked. 6. Press the attention button. The green power LED will start to blink. 56 Installing Accessories

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215

PCI I/O Card Installation
HP 9000 rp8420 servers implement manual retention latch (MRL) hardware for use in online add
or replacement (OLAR) operations. If an MRL is left open while the server is booting, HP-UX
can incorrectly cache PCI slot power status causing OLAR operations to fail. To prevent this
situation, ensure all the MRLs are closed before booting the server.
If OLAR reports that a slot is present and powered off, but no OLAR operations to turn power
on to that slot have succeeded even after the MRL is closed, the MRL may have been left open
during boot. To clear this condition, close the MRL for the PCI slot then power off the PCI slot
using the
rad -o
command. This will allow future OLAR operations to succeed on this PCI
slot.
IMPORTANT:
PCI I/O card installation procedures should be downloaded from the
http://docs.hp.com Web site. Background information and procedures for adding a new PCI I/O
card using online addition are found in the Interface Card OL* Support Guide.
Prerequisites for Adding a PCI I/O Card Using the Attention Button
The prerequisites for this
procedure are:
Drivers for the card have already been installed.
There are no drivers associated with the slot.
The green power LED is steady
OFF
. Should the empty slot be in the
ON
state use the olrad
command or the pdweb tool to power the slot
OFF
.
The yellow attention LED is steady
OFF
or is blinking if a user has requested the slot location.
Refer to the host bus adapter (HBA) documentation for details on card installation.
Run the
olrad -q
command to determine the status of all the PCI I/O slots.
Obtain a copy of the interface card guide for instructions on preparing the operating system
for the online addition of the PCI I/O card before attempting to insert a PCI I/O card into
the PCI-X card cage assembly backplane slot.
CAUTION:
Observe all ESD safety precautions before attempting this procedure. Failure to
follow ESD safety precautions could result in damage to the server.
This procedure describes how to perform an
online addition
of a PCI card using the attention
button for cards whose drivers support OLAR. The attention button is also referred to as the
doorbell.
1.
Remove the top cover.
2.
Remove the PCI bulkhead filler panel.
3.
Flip the PCI manual release latch for the card slot to the open position. Refer to
Figure 3-2
.
4.
Install the new PCI card in the slot.
NOTE:
A slow, firm pressure is needed to properly seat the card into the backplane.
5.
Flip the PCI manual release latch for the card slot to the closed position.
CAUTION:
Working out of sequence or not completing the actions within each step could
cause the system to crash.
Do not press the attention button until the latch is locked.
6.
Press the attention button.
The green power LED will start to blink.
56
Installing Accessories