HP StorageWorks 2/128 HP StorageWorks Core Switch 2/64 and SAN Director 2/128 - Page 105
Verifying operation of the new CP card, haEnable, haShow, Heartbeat Up, State Synchronized, State
View all HP StorageWorks 2/128 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 105 highlights
Verifying operation of the new CP card 1. Verify that boot and POST are complete on the new CP card (which takes a minimum of 3 minutes) and that the CP cards have achieved failover redundancy: a. Wait until the Status LEDs on both CP cards are off. NOTE: The Status LED on the active CP card displays yellow until the active CP card is fully operational, and the Status LED on the standby CP card displays yellow until the CP cards have achieved failover redundancy. b. Enable the redundancy feature by entering the haEnable command from the serial console for the active CP card. c. From the serial console for the active CP card (which should still be the CP card that was not replaced), enter the haShow command and verify that the command output includes HA Enabled, Heartbeat Up, State Synchronized. swDir:admin> hashow Local CP (Slot 5, CP0): Active Remote CP (Slot 6, CP1): Standby HA Enabled, Heartbeat Up, State Synchronized swDir:admin> NOTE: If the command output does not include HA Enabled, Heartbeat Up, State Synchronized, POST is not complete or the CP cards have not yet achieved redundancy. Wait a minute or two and reenter the command to verify that redundancy has been achieved. Core Switch 2/64 and SAN Director 2/128 installation guide 105