HP StorageWorks 2/128 HP StorageWorks Core Switch 2/64 and SAN Director 2/128 - Page 108

Flow control: None, Parity: None

Page 108 highlights

NOTE: If necessary, remove the adapter on the serial cable to allow for a serial RJ45 connection. d. Open the terminal emulator application and configure as follows: • Bits per second: 9600 • Databits: 8 • Parity: None • Stop bits: 1 • Flow control: None 8. Log in to the new CP card as admin. Fabric OS (swDir) swDir login: admin Password: swDir:admin> 9. From the serial console for the new CP card, enter the haFailover command to fail the active CP card over to the new CP card. 10.Verify that the configuration has successfully propagated to the new CP card by checking any configuration parameters for which you have specified nondefault values. To do this, enter the configShow command followed by a filter (a text string in quotes) that relates to the parameter: for example, configShow "fabric". This limits the command output to entries that contain that text string. NOTE: Entering the configShow command without a filter prints out approximately 1000 lines. For more information about this command, refer to the HP StorageWorks command reference guide for the Fabric OS version running on your switch. 108 Installing FRUs

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166

Installing FRUs
108
NOTE:
If necessary, remove the adapter on the serial cable to allow for a serial RJ45
connection.
d.
Open the terminal emulator application and configure as follows:
Bits per second: 9600
Databits: 8
Parity: None
Stop bits: 1
Flow control: None
8.
Log in to the new CP card as admin.
9.
From the serial console for the new CP card, enter the
haFailover
command to fail the
active CP card over to the new CP card.
10.
Verify that the configuration has successfully propagated to the new CP card by checking
any configuration parameters for which you have specified nondefault values. To do this,
enter the
configShow
command followed by a filter (a text string in quotes) that relates to
the parameter: for example,
configShow
”fabric”
. This limits the command output to
entries that contain that text string.
NOTE:
Entering the
configShow
command
without
a filter prints out approximately 1000
lines. For more information about this command, refer to the
HP StorageWorks command
reference guide
for the Fabric OS version running on your switch.
Fabric OS (swDir)
swDir login: admin
Password:
swDir:admin>