HP StorageWorks 2/128 HP StorageWorks Core Switch 2/64 and SAN Director 2/128 - Page 108
Flow control: None, Parity: None
View all HP StorageWorks 2/128 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 108 highlights
NOTE: If necessary, remove the adapter on the serial cable to allow for a serial RJ45 connection. d. Open the terminal emulator application and configure as follows: • Bits per second: 9600 • Databits: 8 • Parity: None • Stop bits: 1 • Flow control: None 8. Log in to the new CP card as admin. Fabric OS (swDir) swDir login: admin Password: swDir:admin> 9. From the serial console for the new CP card, enter the haFailover command to fail the active CP card over to the new CP card. 10.Verify that the configuration has successfully propagated to the new CP card by checking any configuration parameters for which you have specified nondefault values. To do this, enter the configShow command followed by a filter (a text string in quotes) that relates to the parameter: for example, configShow "fabric". This limits the command output to entries that contain that text string. NOTE: Entering the configShow command without a filter prints out approximately 1000 lines. For more information about this command, refer to the HP StorageWorks command reference guide for the Fabric OS version running on your switch. 108 Installing FRUs