Table 9 Power supply LED patterns, Either the switch has
![]() |
View all HP StorageWorks 2/128 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 73 highlights
Table 9 Power supply LED patterns LED location/ Color purpose Power No light (LED is off) Steady green Predictive Failure No light (LED is off) Flashing orange Failure No light (LED is off) Steady orange Flashing orange Status Recommended action Power supply is not receiving power and is not providing power to the switch. Ensure power supply is firmly seated, switch is receiving power, both power cables are connected, and AC power switches are on. Power supply is receiving power and is providing power to the switch. No action required. Power supply is either Check the power LED. healthy or is not receiving power. Power supply is about to fail due to a failing fan inside the power supply. Replace power supply. Power supply is either Check the power LED. healthy or is not receiving power. Either the switch has power but this power supply does not (AC switch may be off) or the power supply has failed. Verify that the correct AC power switch is on and power supply is seated. If orange light continues, replace power supply. Power supply is unable to supply power. Verify that the incoming power meets power requirements (refer to "Technical specifications" on page 135). Core Switch 2/64 and SAN Director 2/128 installation guide 73