HP StoreOnce D2D4324 HP D2D Gen2E Backup Systems Maintenance and Service Guide - Page 19
The HP SmartArray P410i and P411 RAID controllers and HP SAS expander card (HP D2D4312), Overview
![]() |
View all HP StoreOnce D2D4324 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
5 The HP SmartArray P410i and P411 RAID controllers and HP SAS expander card (HP D2D4312) Overview The HP D2D4312 has three RAID controllers. • The P410i RAID controller is integral to the DL370G6 motherboard and is used to control the 12 hard disk drives internal to the HP D2D4312 via the HP SAS Expander card in slot 1. • The two P411 cards are used to connect the external storage shelves to the D2D 4312 and are located in PCI-e slots 5 and 6. • Each P410i and P411 RAID controller is fitted with 512 MB RAM and one 512 MB FBWC (Flash Backed Write Cache). NOTE: If you replace a motherboard with integral P410i card, or a P411 card, you must add the RAID 6 license for the card, as described in the relevant sections below. Figure 13 HP D2D4312, location of the P411 controller and HP SAS expander card 1 and 2 P411 RAID controllers 3 HP SAS expander card WARNING! To reduce the risk of personal injury or damage to the equipment, consult the safety information and user documentation provided with the server and RAID controllers before attempting the installation. Part numbers Part numbers for the replacement RAID controllers are as follows: • The P410i card is integral to the motherboard and cannot be replaced separately. • HP D2D4312: HP Smart Array P411/512 MB with FBWC Controller: 578229-B21 Identifying a RAID contoller failure RAID card failures are reported in the Log and in email alerts, if you have set them up. For example: cache module failure. You can identify which card has failed by looking at the Storage-RAID pages of the Web Management Interface. The P410i card is identified as "internal"; the P411 cards are identified by their slot number in the Controllers section. Any issues with logical units on this page also indicate a problem. If the HP SAS expander card is at fault, disks will not be visible on the Storage-Shelves tab Overview 19
![](/manual_guide/products/hewlettpackard-d2d2502i-hp-d2d-gen2e-backup-systems-maintenance-service-guide-eh98590947-2012-4019829/19.png)