Page 290 highlights
Adaptec SCSI RAID Software Reference Guide AAC0>enclosure set temperature 0 100 Executing: enclosure set temperature 0 100 You may want to use the enclosure show temperature command again to see the change in threshold temperature, as in the following example: AAC0>enclosure show temperature 0 Executing: enclosure show temperature 0 Enclosure Sensor Temperature Threshold Status 0 0 70 F 100 NORMAL The Threshold column now displays 100 degrees. Related Information enclosure commands: ■ enclosure list (page 11-7) ■ enclosure show temperature (page 11-41) 11-26
![](/manual_guide/products/hewlettpackard-xw8200-adaptec-scsi-raid-2120s-software-reference-guide-ea1ed4a/290.png)
11-26
Adaptec SCSI RAID Software Reference Guide
AAC0>enclosure set temperature 0 100
Executing: enclosure set temperature 0 100
You may want to use the
enclosure show temperature
command again to see the change in threshold temperature, as in
the following example:
AAC0>enclosure show temperature 0
Executing: enclosure show temperature 0
Enclosure Sensor Temperature Threshold Status
--------- ------ ----------- --------- --------
0
0
70 F
100
NORMAL
The
Threshold
column now displays
100
degrees.