Hitachi HDT725025VLA380 Specifications - Page 129
Command Block Input Registers Success
UPC - 829686001084
View all Hitachi HDT725025VLA380 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 129 highlights
Command Block Input Registers (Success) Error 00h Sector Count If Function Code was 0002h, then this is the LSB of the requested recovery limit. Otherwise, this field is reserved. Sector Number If Function Code was 0002h, then this is the MSB of the requested recovery limit. Otherwise, this field is reserved. Cylinder Low reserved Cylinder High reserved Device/Head reserved Status 50h The Error Recovery Control command can be used to set time limits for read and write error recovery. For nonqueued commands, these timers apply to command completion at the host interface. For queued commands where in order data delivery is enabled, these timers begin counting when the device begins to execute the command, not when the command is sent to the device. These timers do not apply to streaming commands, or to queued commands when out-of-order data delivery is enabled. These command timers are volatile. The default value is 0 (i.e. disable command time-out). Deskstar T7K500 Hard Disk Drive Specification 115