Execute Device Diagnostic 90h
UPC - 829686001084
View all Hitachi HDT725025VLA380 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 156 highlights
12.5 Execute Device Diagnostic (90h) Table 76: Execute Device Diagnostic command (90h) Command Block Output Registers Register 7 6 5 4 3 2 1 0 Data Feature Sector Count Sector Number Cylinder Low Cylinder High Device/Head 1 - 1 - - - - - Command 1 0 0 1 0 0 0 0 Command Block Input Registers Register 7 6 5 4 3 2 1 0 Data Error see below Sector Count Sector Number Cylinder Low Cylinder High Device/Head Status see below 76 CRC UNC VV Error Register 54 3 2 1 0 0 IDN 0 ABT T0N AMN VV V V V V Status Register 7 654 3 2 1 0 BSY RDY DF DSC DRQ COR IDX ERR 0 V0- - 0 - 0 The Execute Device Diagnostic command performs the internal diagnostic tests implemented by the device. The results of the test are stored in the Error Register. The normal Error Register bit definitions do not apply to this command. Instead, the register contains a diagnostic code. See Table 57: "Default Register Values" on page 78 for the definition. Deskstar T7K500 Hard Disk Drive Specification 142