Hitachi HDT725025VLA380 Specifications - Page 134
SCT Data Table Command action code: 0005h, Field Name, Description
UPC - 829686001084
View all Hitachi HDT725025VLA380 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 134 highlights
10.18.2.5 SCT Data Table Command (action code: 0005h) Word 0 1 2 255:2 Name Action Code Function Code Table ID reserved Value 0005h 0001h Word 0000h Description Read a data table Read Table See Error! Reference source not found. for a list of data tables Command Block Input Registers (Success) Error 00h Sector Count reserved Sector Number reserved Cylinder Low Number of sectors to transfer (LSB) = 01h Cylinder High Number of sectors to transfer (MSB) = 00h Device/Head reserved Status 50h Table ID 0000h 0001h 0002h 0003h-CFFFh D000h-FFFFh Description Invalid Reserved HDA Temperature History Table (in absolute degree C). See Error! Reference source not found. Reserved Vendor Specific Byte Size Field Name Description 1:0 Word Format Version Data table format version (=0002h) 3:2 Word Sampling Absolute HDA Temperature sampling period in Period minutes. 000h indicates sampling is disabled. 5:4 Word Interval Timer interval between entries in the history queue. Deskstar T7K500 Hard Disk Drive Specification 120