Hunter 44660 User Guide - Page 49

Wiring Diagrams

Page 49 highlights

WIRING DIAGRAMS Wallplate Terminals G Jumper Rc Rc1 Rh Y/O W/B Y1 Fan Heat/Cool Cool Heat Relay Relay 24V Supply Contactor or Valve System Selector HG/HE - SSHP 4-Wire Heat/ Cool System Wallplate Terminals G Rc Rc1 Rh Y/O W/B Y1 Fan Cool 24V Heat 24V Cool Heat Relay Relay Supply Supply Contactor or Valve System Selector HG/HE - SSHP 5-Wire Heat/ Cool System Wallplate Terminals G Fan Relay Jumper Rc Rc1 Rh Y/O W/B Y1 Cool Mode OR Heat Mode Heat Pump 24V Supply Reversing Valve Compressor Contactor Connect to proper Reversing Valve Terminal. See Table A System Selector HG/HE - SSHP Single-Stage Heat Pump System 49 Wallplate Terminals Jumper G Rc Rc1 Rh Y/O W/B Y1 Heat 24V or Millivolt Supply Heat Relay or Valve System Selector HG/HE - SSHP 2-Wire Heat Only System Wallplate Terminals G Jumper Rc Rc1 Rh Fan Heat 24V Relay Supply Y/O W/B Heat Relay or Valve System Selector HG/HE - SSHP Y1 3-Wire Heat Only System Wallplate Terminals Jumper G Rc Rc1 Rh Y/O W/B Y1 Fan Cool 24V Relay Supply Heat Relay or Valve System Selector HG/HE - SSHP 3-Wire Cool Only System

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100

49
WIRING DIAGRAMS
Y/O
W/B
Y1
G
Fan
Relay
Rc1
Rc
Heat/Cool
24V Supply
Rh
Cool
Contactor
Heat Relay
or Valve
Wallplate
Terminals
Jumper
System
Selector
HG/HE - SSHP
Y/O
W/B
Y1
G
Fan
Relay
Rc1
Rc
Heat 24V
Supply
Rh
Heat Relay
or Valve
Cool
Contactor
Wallplate
Terminals
Cool 24V
Supply
System
Selector
HG/HE - SSHP
Y/O
W/B
Y1
G
Fan
Relay
Rc1
Rc
Heat Pump
24V Supply
Rh
Cool
Mode
Reversing
Valve
Wallplate
Terminals
Jumper
Heat
Mode
OR
Compressor
Contactor
Connect to proper Reversing
Valve Terminal. See Table A
System
Selector
HG/HE - SSHP
Y/O
W/B
Y1
G
Heat Relay
or Valve
Rc1
Rc
Heat 24V or
Millivolt Supply
Rh
Wallplate
Terminals
Jumper
System
Selector
HG/HE - SSHP
Y/O
W/B
Y1
G
Fan
Relay
Rc1
Rc
Heat 24V
Supply
Rh
Heat Relay
or Valve
Wallplate
Terminals
Jumper
System
Selector
HG/HE - SSHP
Y/O
W/B
Y1
G
Fan
Relay
Rc1
Rc
Cool 24V
Supply
Rh
Heat Relay
or Valve
Wallplate
Terminals
Jumper
System
Selector
HG/HE - SSHP
4-Wire Heat/
Cool System
5-Wire Heat/
Cool System
Single-Stage
Heat Pump
System
2-Wire Heat
Only System
3-Wire Heat
Only System
3-Wire Cool
Only System