96 Global Console Switch Installer and User Guide Table D.1: GCM2 and GCM4 appliance product specifications (Continued) Dimensions Height x Width x Depth 1.72 in. x 17.00 in.x 10.98 in.; 1-U form factor (4.37 cm x 43.18 cm x 27.98 cm) Weight 7.3 lbs (3.31 kg) without cables Power Supply Heat dissipation 92 BTU/Hr Airflow 8 CFM Power consumption 12.5 Watts AC-input power 40 Watts maximum AC-input voltage rate 100 to 240 V ac Autosensing AC-input current rating 0.5 A AC-input cable 18 AWG three-wire cable, with a three-lead IEC-320 receptacle on the power supply end and a country-dependent connector on the power resource end AC frequency 50 to 60 Hz autosensing Ambient atmospheric condition ratings Temperature 0o to 50o Celsius (32o to 122o Farenheit) operating -20o to 60o Celsius (-4o to 140o Farenheit) nonoperating Humidity 20 to 80% noncondensing operating 5 to 95% noncondensing nonoperating Safety and EMC approvals and markings UL, FCC, cUL, ICES, CE, N, GS, IRAM, GOST, VCCI, MIC, C-Tick