IBM 6400-I15 Maintenance Manual - Page 188
Coil Temp, Vice / Set Coil Tempera
![]() |
View all IBM 6400-I15 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 188 highlights
Coil Temperature Adjustment IMPORTANT This procedure applies only to models 6400-014 and 6400-015. Do this procedure only when the original CMX controller board or shuttle frame assembly have been replaced. Do not do this procedure if the original CMX board or shuttle frame assembly were removed and reinstalled as part of other maintenance tasks. The shuttle frame assembly must be at room temperature to do this procedure. 1. Raise the printer cover. 2. Power on the printer. 3. If the Ready indicator is on, press the Stop key. The printer must be in the NOT READY state to do this procedure. 4. Press Scroll" + Scroll# + Return + Enter. (Press all four keys at the same time.) "SERVICE / PRINTER MECHANISM TESTS" appears on the display. 5. Press Scroll" + Scroll# to unlock the Enter key. 6. Press the Scroll" or Scroll# key until "SERVICE / SET COIL TEMPERATURE" appears on the display. 7. Press Enter. The display tells you to "PLEASE WAIT" while the coil temperature is set by an automatic calibration sequence in printer software. 8. When the display again reads "SERVICE / SET COIL TEMPERATURE" press Scroll" + Scroll# to lock the Enter key. 9. Press Stop to exit the menu and put the printer in the NOT READY state. -OR- 10. Press Start to exit the menu and put the printer in the READY state. 11. Coil temperature is now set. Power off the printer and close the printer cover. 188 Adjustment Procedures