MPU Asm, If the gap is 0.010
![]() |
View all IBM 6400-I15 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 223 highlights
Magnetic Pick-up (MPU) Assembly Removal 1. Prepare the printer for maintenance (page 194). 2. Remove the shuttle cover (page 209). 3. Disconnect the shuttle cable assembly connector (page 275, Figure 45). 4. Disconnect the magnetic pick-up (MPU) cable connector (page 279, Figure 47). 5. Loosen the 7/64 inch hex MPU clamp screw (page 279, Figure 47). 6. Unscrew the MPU assembly from the MPU bracket. Installation 1. Install the MPU assembly by screwing it into the MPU bracket (page 279, Figure 47). 2. Using a feeler gauge, adjust the gap between the MPU assembly and the flywheel to 0.010 ± .001 inch (0.254 ± 0.025 mm). Torque the MPU clamp screw to 19 ± 1 inch-pounds (2.15 ± 0.11 NSm). 3. Check the gap between the MPU assembly and the flywheel with a feeler gauge: a. If the gap is 0.010 ± .001 inch (0.254 ± 0.025 mm), go to step 4. b. If the gap is not 0.010 ± 0.001 inch (0.254 ± 0.025 mm), loosen the MPU clamp screw and go back to step 2. ATTENTION Make sure the MPU cable is below the extension spring and does not touch the spring after the cable is connected. 4. Connect the magnetic pick-up (MPU) cable connector. 5. Connect the shuttle cable assembly connector (page 279, Figure 47). 6. Install the shuttle cover (page 209). 7. Adjust the hammer phasing (page 179.) 8. Return the printer to normal operation (page 159). Replacement Procedures and Illustrated Parts List 223
![](/manual_guide/products/ibm-6400i15-maintenance-manual-bffea60/223.png)