IBM 6400-I15 Maintenance Manual - Page 196
Cabinet Model: Install the barrier shield and tighten the four screws.
View all IBM 6400-I15 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 196 highlights
Installation 1. Install the paper feed timing belt over the splined shaft pulley and the motor pulley. Slide the motor pulley onto the paper feed motor shaft (page 285, Figure 50). 2. Holding a 0.040 inch feeler gauge between the pulley collar and the motor body, torque the 7/64 inch collar screw to 25 ± 2 inch-pounds (2.82 ± 0.23 NSm). 3. Using the straight end of a force gauge, apply 15 pounds (66.7 N) of pressure to the paper feed drive motor near the mounting base of the motor. Use the splined shaft to steady the gauge. 4. Reduce tension to 12 pounds (53.4 N) and torque the paper feed motor mount bolts to 18 ± 2 inch-pounds (2.03 ± 0.23 NSm). 5. Snap the timing belt cover into the slots in the side plate (page 269, Figure 43). 6. Cabinet Model: Install the barrier shield and tighten the four screws. (See page 269, Figure 43, items 3 and 4.) Pedestal Model: Install the barrier shield and paper guide and tighten the four screws. (See page 271, Figure 44, items 3, 4, and 5.) 7. Cabinet Model: Install the paper guide assembly (page 235). Pedestal Model: Install the top cover assembly (page 210). 8. Return the printer to normal operation (page 159). 196 Replacement Procedures and Illustrated Parts List