IBM 6400-I15 Maintenance Manual - Page 244
Ribbon Guide Asm
View all IBM 6400-I15 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 244 highlights
Ribbon Guide Assembly (L/R) Removal 1. Prepare the printer for maintenance (page 194). 2. Open the printer cover. 3. Remove the printer ribbon. NOTE: The right ribbon guide is shown in Figure 50. The removal procedure is the same for the left ribbon guide. 4. Cut and remove the tie-wrap from the tie wrap hole to free the ribbon guide cable (page 285, Figure 50). 5. Cabinet Model: Remove the paper guide assembly (page 235). Pedestal Model: Remove the top cover assembly (page 210). 6. Trace the ribbon guide cable back to the controller board, releasing it from the cable restraints. (See cable routing diagram on page 306.) 7. For the left ribbon guide, disconnect connector shell P106 from the controller board. For the right ribbon cable, disconnect connector shell P107 from the controller board. 8. Trace the ribbon guide wires to the connector shell, and remove the cable connector from the connector shell (page 198). 9. Remove the two screws and washers securing the ribbon guide assembly to the side plate. 10. Slide the ribbon guide assembly out of the side plate. Installation NOTE: The right ribbon guide is shown in Figure 50. The installation procedure is the same for the left ribbon guide. 1. Reverse steps 4 through 10 of the removal procedure above. 2. Align the ribbon guides (page 172). 3. Return the printer to normal operation (page 159). 244 Replacement Procedures and Illustrated Parts List