Diagnostic error codes In the following index, "X" can represent any number. Diagnostic Error Code 000-000-XXX BIOS Test Passed 000-002-XXX BIOS Timeout 000-024-XXX BIOS Addressing test failure 000-025-XXX BIOS Checksum Value error 000-026-XXX FLASH data error 000-027-XXX BIOS Configuration/Setup error 000-034-XXX BIOS Buffer Allocation failure 000-035-XXX BIOS Reset Condition detected 000-036-XXX BIOS Register error 000-038-XXX BIOS Extension failure 000-039-XXX BIOS DMI data error 000-195-XXX BIOS Test aborted by user 000-196-XXX BIOS test halt, error threshold exceeded 000-197-XXX BIOS test warning FRU/Action 1. No action 1. Flash the system 2. System board 1. Flash the system 2. System board 1. Flash the system 2. Boot block 3. System board 1. Flash the system 2. Boot block 3. System board 1. Run Setup 2. Flash the system 3. Boot block 4. System board 1. Reboot the system 2. Flash the system 3. Run memory test 4. System board 1. Flash the system 2. System board 1. Flash the system 2. Boot block 3. System board 1. Flash the system 2. Adapter card 3. System board 1. Flash the system 2. System board 1. Information 2. Re-start the test, if need to 1. Depress F3 to review the log file. 2. Re-start the test to reset the log file. 1. Make sure component that is called out is enabled and/or connected 2. Re-run test 3. Component that is called out in warning statement 4. Component under test 166 Netfinity Server HMM