IBM FAStT500 User Guide - Page 47

Statement 4, CAUTION, Use safe practices when lifting., on the inside rear of the controller unit.

Page 47 highlights

Statement 4 ≥ 18 kg (37 lbs) ≥ 32 kg (70.5 lbs) CAUTION: Use safe practices when lifting. ≥ 55 kg (121.2 lbs) 10 Slide the controller unit out of the rack and set it on a level, dry surface. 11 If you are shipping the controller unit to another location, replace all CRUs in the controller unit. Carefully pack the unit in its original shipping container. You are finished with this procedure. 12 If you are moving the controller unit to another cabinet, remove the support rails and power cords from the old cabinet and install them in the new one. 13 To replace the controller unit and components, using the proper cautions, reverse Step 1 on page 25 through Step 10, as follows: a Slide the controller unit into the rack. b Insert and tighten two of the screws that you removed in Step 9 on page 26, on the inside front of the controller unit. c Insert and tighten the remaining two screws that you removed in Step 9 on page 26, on the inside rear of the controller unit. d Replace all CRUs in the controller unit. e Connect the interface cables and host Fibre Channel cables that you labeled in Step 7 on page 26. f Connect the remaining cables to the controller unit. g Turn on the main circuit breakers or power switches. h Plug in the power cords to the controller unit; then, turn on both power switches. Chapter 2. Operating the controller unit 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90

Chapter 2. Operating the controller unit
27
Statement 4
10
Slide the controller unit out of the rack and set it on a level, dry surface.
11
If you are shipping the controller unit to another location, replace all CRUs in the
controller unit. Carefully pack the unit in its original shipping container. You are
finished with this procedure.
12
If you are moving the controller unit to another cabinet, remove the support rails and
power cords from the old cabinet and install them in the new one.
13
To replace the controller unit and components, using the proper cautions, reverse
Step
1 on page 25
through
Step 10
, as follows:
a
Slide the controller unit into the rack.
b
Insert and tighten two of the screws that you removed in
Step 9 on page 26
, on the
inside front of the controller unit.
c
Insert and tighten the remaining two screws that you removed in
Step 9 on page 26
,
on the inside rear of the controller unit.
d
Replace all CRUs in the controller unit.
e
Connect the interface cables and host Fibre Channel cables that you labeled in
Step 7 on page 26
.
f
Connect the remaining cables to the controller unit.
g
Turn on the main circuit breakers or power switches.
h
Plug in the power cords to the controller unit; then, turn on both power switches.
18 kg (37 lbs)
32 kg (70.5 lbs)
55 kg (121.2 lbs)
CAUTION:
Use safe practices when lifting.