Icom IC-M220 Instruction Manual - Page 57
MBF-5 installation
View all Icom IC-M220 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 57 highlights
9 CONNECTIONS AND MAINTENANCE ■■ MBF-5 installation The optional MBF-5 flush mount kit is for mounting the transceiver to a flat surface (less than 20 mm thick), such as an instrument panel. 1 NOTE: Install the transceiver and/or microphone more than 1 meter from the vessel's 2 magnetic navigation compass. 3 1. Using the template on page 51, carefully cut a hole in the instrument panel, or wherever you plan 4 to mount the transceiver. 2. Slide the transceiver through the hole, as shown 5 to the right. 6 7 3. Attach the 2 bolts (5 × 8 mm) and spacer 8 supplied with the MBF-5 to both sides of the transceiver. (Torque: 2 N•m) 9 10 11 4. Attach the clamps on both sides of the 12 transceiver. LL Make sure that the clamps align parallel to the 13 transceiver body. 14 Clamp 5. Tighten the end bolts on the clamps (rotate clockwise) so that the clamps press firmly against the inside of the instrument control panel. 15 16 17 18 End bolt 6. Tighten the locking nuts (rotate counterclockwise) so that the transceiver is securely mounted in position, as shown to the right. (Torque: 2 N•m) 7. Connect the antenna and power cable. Locking nut 47