Icom IC-PW1 Instruction Manual - Page 12

transceivers, transceivers when the, IC-PW1's power is OFF

Page 12 highlights

2 INSTALLATION AND CONNECTIONS • Using 1 Icom and 1 non-Icom exciters (transceivers) NOTE: The specifications for the SEND relay are 5 V DC 0.1 A. If this level is exceeded, a large external relay must be used. To an ACC-1 antenna ANT REMOTE Be sure to connect the cable to the 7-pin ACC(2) jack. ACC cable (supplied) Remote control cable (supplied) Coaxial cable (supplied) INPUT1 INPUT2 GND ACC(2) Connect ANT1 or ANT2 REMOTE IC-756 EXCITER 1 1&2 GND Non-Icom exciter ANT IC-PW1 AC outlet Coaxial cable Ground (optional) (Non-Europe versions : 100-120/220-240 V Europe version : 230 V) SEND SEND2  SEND RF OUT GND SEND DC OUT ALC ALC2 RCA plug Relay DC power ALC • Using non-Icom exciters (transceivers) when the IC-PW1's power is OFF To use the antenna selector of the IC-PW1 when the IC-PW1 power is OFF, follow 1 of 2 methods. (1) Supply the antenna selector power to the ACC-1 socket Supply the 13.8 V DC, 0.5 A to pin 7 of the [ACC-1]/[ACC-2] socket. - Use [ACC-1] when the exciter is con- nected to [INPUT1]. - Use [ACC-2] when the exciter is con- nected to [INPUT2]. to IC-PW1 [INPUT1] 13.8 V DC [ACC-1] to IC-PW1 [GND] 6 3 1 RF GND 524 DC SEND ALC IC-PW1 (DIN) Non-Icom exciter (2) Use the auxiliary power supply Set the jumper to '2' to use the auxiliary power supply as shown at right. - The antenna selector functions even when the IC-PW1 power is OFF In addition set the jumper on the IC-PW1 controller to '2' to turn the controller's LEDs OFF as shown at right. When the jumper is set to '2,' the CI-V control does not function even if an Icom exciter is connected. •Jumper location of linear amplifier S3 J3 J4 2 1 • Jumper location of controller 12 These diagrams show the factory defaults. 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

9
2
INSTALLATION AND CONNECTIONS
•Using 1 Icom and 1 non-Icom exciters
(transceivers)
NOTE:
The specifications for the SEND relay are
5 V DC 0.1 A. If this level is exceeded, a large ex-
ternal relay must be used.
•Using non-Icom exciters
(transceivers) when the
IC-PW1’s power is OFF
To use the antenna selector of the
IC-PW1 when the IC-PW1 power
is OFF, follow 1 of 2 methods.
(1) Supply the antenna selector
power to the ACC-1 socket
Supply the 13.8 V DC, 0.5 A to pin
7 of the [ACC-1]/[ACC-2] socket.
- Use [ACC-1] when the exciter is con-
nected to [INPUT1].
- Use [ACC-2] when the exciter is con-
nected to [INPUT2].
(2) Use the auxiliary power
supply
Set the jumper to ‘2’ to use the
auxiliary power supply as shown at
right.
-The antenna selector functions even
when the IC-PW1 power is OFF
In addition set the jumper on the
IC-PW1 controller to ‘2’ to turn the
controller’s LEDs OFF as shown at
right.
When the jumper is set to ‘2,’
the CI-V control does not func-
tion even if an Icom exciter is
connected.
These diagrams show the factory de-
faults.
J3
J4
S3
12
1
2
•Jumper location of linear amplifier
•Jumper location of controller
1
2
3
4
5
6
SEND ALC
RF
DC
GND
[ACC-1]
13.8 V DC
to IC-PW1 [INPUT1]
to IC-PW1 [GND]
IC-PW1 (DIN)
Non-Icom exciter
ANT
ACC-1
ANT
ACC(2)
REMOTE
REMOTE
INPUT1
INPUT2
Connect
ANT1 or
ANT2
GND
GND
IC-PW1
IC-756
Ground
Coaxial cable (supplied)
Coaxial cable
(optional)
ACC cable (supplied)
Remote control cable (supplied)
To an
antenna
EXCITER
1
1&2
RCA plug
ALC
ALC2
SEND2
SEND
SEND
Relay
DC power
Non-Icom exciter
GND
RF OUT
ALC
DC OUT
SEND
Be sure to connect the cable to the 7-pin ACC(2) jack.
AC outlet
(Non-Europe versions : 100–120/220–240 V
Europe version