Page 4 highlights

Remote control DDCommand table Cmd. 00 01 02 03 04 05 06 07 08 Sub cmd. A0 09 0A 0B 0C 0D 0E 00 01 02 03 04 12 13 22 23 24 42 A0 AA Ax B0 B1 B2 D0 D1 D3 0F 10 11 12 10* Data See p. 9 See p. 9 See p. 9 See p. 9 See p. 9 See p. 9 See p. 9 0000 ~ 0199 0000 ~ 0102 See p. 9 01 ~ 09 00 ~ 09 10 ~ 12 00 01 02 03 04 05 06 07 08 09 10 11 Description Output the frequency data for transceive Output the receiving mode for transceive Read the band edge frequencies Read the receiving frequency Read the receiving mode Set the receiving frequency Select the receiving mode Select the VFO mode Select the Memory mode Select the Memory channel (0000 ~ 0099: Normal Memory channels/Scan Skip channels/Scan edges) (0000 ~ 0199: Auto Memory Write channels) Select the Memory group (0000 ~ 0099: Normal Memory channels 0100: Auto Memory Write channels 0101: Scan Skip channels 0102: Scan edges) Memory write mode Memory copy to VFO Memory clear Read offset frequency Set offset frequency Scan stop Programmed/memory scan start Programmed scan start ∂F scan start Auto Memory Write scan start Fine Programmed scan start Fine ∂F scan start Memory scan start Select memory scan start Mode Select scan start Priority scan start Set the Fix of ∂F frequency to OFF Set the Fix of ∂F frequency to ON Set/read the Fix range (x) of ∂F frequency (1=±5kHz, 2=±10kHz, 3=±20kHz, 4=±50kHz, 5=±100kHz, 6=±500kHz, 7=±1MHz) Set as non-select channel Set as select channel (If no selection is performed, the previously set number by CI-V is set after turning power ON, otherwise "1" is automatically set.) Set as select channel (01=SEL1, 02=SEL2, 03=SEL3, 04=SEL4, 05=SEL5, 06=SEL6, 07=SEL7, 08=SEL8, 09=SEL9) Set starting select memory channel for a select memory scan (00=ALL, 01=SEL1, 02=SEL2, 03=SEL3, 04=SEL4, 05=SEL5, 06=SEL6, 07=SEL7, 08=SEL8, 09=SEL9) Set Scan resume OFF Set Scan resume ON (PAUSE TIME=HOLD) Set Scan resume ON Read duplex setting (10=OFF, 11=DUP-, 12=DUP+) Set Simplex Set Duplex - Set Duplex + Send/read the tuning step OFF (in 10 Hz steps) Send/read the 100 Hz tuning step Send/read the 1 kHz tuning step Send/read the 2.5 kHz tuning step Send/read the 3.125 kHz tuning step Send/read the 5 kHz tuning step Send/read the 6.25 kHz tuning step Send/read the 8.33 kHz tuning step Send/read the 9 kHz tuning step Send/read the 10 kHz tuning step Send/read the 12.5 kHz tuning step Send/read the 20 kHz tuning step Cmd. Sub cmd. 10* 11* 12* 13 00 01 02 14* 01 02 03 06 07 08 09 0D 12 19 1B 1C 1D 1E 1F 20 15 01 02 03 04 05 06 07 Data 12 13 14 00 10 20 30 00 ~ 02 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 00/01 0000 ~ 0255 0000 ~ 0255 00/01 00/01 00/01 Description Send/read the 25 kHz tuning step Send/read the 100 kHz tuning step Send/read the programmable tuning step Send/read Attenuator OFF (0 dB) Send/read Attenuator (10 dB) Send/read Attenuator (20 dB) Send/read Attenuator (30 dB) Select antenna (only 10 kHz - 29.999999 MHz) (00=ANT1, 01=ANT2, 02=ANT3) Speech all parameters (Signal level + Frequency + Receiving mode) Speech frequency (Signal level + Frequency) Speech receiving mode LThe mode is announced after the ongoing speech. Send/read the AF gain level (0000=Minimum ~ 0255=Maximum) Send/read the RF gain level (0000=Minimum ~ 0255=Maximum) Send/read the squelch level (0000=Minimum ~ 0255=Maximum) Send/read the NR level (0000=0% ~ 0255=100%) Send/read the PBT1 position (0000=Narrow the upper edge, 0128=Center position, 0255=Narrow the lower edge) Send/read the PBT2 position (0000=Narrow the upper edge, 0128=Center position, 0255=Narrow the lower edge) Send/read CW pitch (0000=300 Hz, 0128=600 Hz, 0255=900 Hz) (in 5 Hz steps) Send/read the NOTCH position (0000=A lower position, 0128=Center position, 0255=A upper position) Send/read the NB level (0000=0% ~ 0255=100%) Send/read the LCD brightness (0000=0% ~ 0255=100%) Send/read the tone (Bass) level (0000=-15, 0128=0, 0255=+15) Send/read the tone (Treble) level (0000=-15, 0128=0, 0255=+15) Send/read the Scan Speed (0000=1, 0128=16, 0255=30) Send/read the Scan Delay (0000=1s, 0128=16s, 0255=HOLD) Send/read the PRIO Interval (0000=1s, 0128=8s, 0255=15s) Send the RESUME TIME (0000=0s, 0128=4s, 0255=HOLD) Read noise or S-meter squelch status (00=Close, 01=Open) Read the S-meter level (0000=S0, 0120=S9, 0241=S9+60dB) Read the meter level in the "AAAABBCC" Format: AAAA= Absolute signal strength (in 0.1 steps) BB= P lus or minus sign (00=+, 01=-) CC= M eter type (00=dBμ, 01=dBμ EMF, 02=dBm) Read the center meter level (0000= Left edge, 0128= Center, 0255= Right edge) Read various squelch function's (including the tone squelch) status (00=Close, 01=Open) Read the S-AM SYNC Indicator (00=Non-synchronous, 01=Synchronous) Read the OVF indicator status (00=OFF, 01=ON) 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

Cmd.
Sub cmd.
Data
Description
00
See p. 9
Output the frequency data for transceive
01
See p. 9
Output the receiving mode for transceive
02
See p. 9
Read the band edge frequencies
03
See p. 9
Read the receiving frequency
04
See p. 9
Read the receiving mode
05
See p. 9
Set the receiving frequency
06
See p. 9
Select the receiving mode
07
Select the VFO mode
08
Select the Memory mode
0000 ~ 0199
Select the Memory channel
(0000 ~ 0099: Normal Memory
channels/Scan Skip
channels/Scan edges)
(0000 ~ 0199:
Auto Memory Write channels)
A0
0000 ~ 0102
Select the Memory group
(0000 ~ 0099:
Normal Memory channels
0100: Auto Memory Write channels
0101: Scan Skip channels
0102: Scan edges)
09
Memory write mode
0A
Memory copy to VFO
0B
Memory clear
0C
Read offset frequency
0D
See p. 9
Set offset frequency
0E
00
Scan stop
01
Programmed/memory scan start
02
Programmed scan start
03
F scan start
04
Auto Memory Write scan start
12
Fine Programmed scan start
13
Fine
F scan start
22
Memory scan start
23
Select memory scan start
24
Mode Select scan start
42
Priority scan start
A0
Set the Fix of
F frequency to OFF
AA
Set the Fix of
F frequency to ON
Ax
Set/read the Fix range (x) of
F frequency
(1=±5kHz, 2=±10kHz, 3=±20kHz,
4=±50kHz, 5=±100kHz, 6=±500kHz,
7=±1MHz)
B0
Set as non-select channel
B1
Set as select channel
(If no selection is performed, the
previously set number by CI-V is set
after turning power ON, otherwise “1” is
automatically set.)
01 ~ 09
Set as select channel
(01=SEL1, 02=SEL2, 03=SEL3,
04=SEL4, 05=SEL5, 06=SEL6,
07=SEL7, 08=SEL8, 09=SEL9)
B2
00 ~ 09
Set starting select memory channel for a
select memory scan
(00=ALL,
01=SEL1, 02=SEL2,
03=SEL3, 04=SEL4, 05=SEL5,
06=SEL6, 07=SEL7, 08=SEL8,
09=SEL9)
D0
Set Scan resume OFF
D1
Set Scan resume ON (PAUSE TIME=HOLD)
D3
Set Scan resume ON
0F
10 ~ 12
Read duplex setting
(10=OFF, 11=DUP–, 12=DUP+)
10
Set Simplex
11
Set Duplex –
12
Set Duplex +
10*
00
Send/read the tuning step OFF (in
10 Hz steps)
01
Send/read the 100 Hz tuning step
02
Send/read the 1 kHz tuning step
03
Send/read the 2.5 kHz tuning step
04
Send/read the 3.125 kHz tuning step
05
Send/read the 5 kHz tuning step
06
Send/read the 6.25 kHz tuning step
07
Send/read the 8.33 kHz tuning step
08
Send/read the 9 kHz tuning step
09
Send/read the 10 kHz tuning step
10
Send/read the 12.5 kHz tuning step
11
Send/read the 20 kHz tuning step
Cmd.
Sub cmd.
Data
Description
10*
12
Send/read the 25 kHz tuning step
13
Send/read the 100 kHz tuning step
14
Send/read the programmable tuning step
11*
00
Send/read Attenuator OFF (0 dB)
10
Send/read Attenuator (10 dB)
20
Send/read Attenuator (20 dB)
30
Send/read Attenuator (30 dB)
12*
00 ~ 02
Select antenna (only 10 kHz –
29.999999 MHz)
(00=ANT1, 01=ANT2, 02=ANT3)
13
00
Speech all parameters
(Signal level + Frequency + Receiving
mode)
01
Speech frequency
(Signal level + Frequency)
02
Speech receiving mode
L
The mode is announced after the
ongoing speech.
14*
01
0000 ~ 0255
Send/read the AF gain level
(0000=Minimum ~ 0255=Maximum)
02
0000 ~ 0255
Send/read the RF gain level
(0000=Minimum ~ 0255=Maximum)
03
0000 ~ 0255
Send/read the squelch level
(0000=Minimum ~ 0255=Maximum)
06
0000 ~ 0255
Send/read the NR level
(0000=0% ~ 0255=100%)
07
0000 ~ 0255
Send/read the PBT1 position
(0000=Narrow the upper edge,
0128=Center position,
0255=Narrow the lower edge)
08
0000 ~ 0255
Send/read the PBT2 position
(0000=Narrow the upper edge,
0128=Center position,
0255=Narrow the lower edge)
09
0000 ~ 0255
Send/read CW pitch
(0000=300 Hz, 0128=600 Hz,
0255=900 Hz) (in 5 Hz steps)
0D
0000 ~ 0255
Send/read the NOTCH position
(0000=A lower position,
0128=Center position,
0255=A upper position)
12
0000 ~ 0255
Send/read the NB level
(0000=0% ~ 0255=100%)
19
0000 ~ 0255
Send/read the LCD brightness
(0000=0% ~ 0255=100%)
1B
0000 ~ 0255
Send/read the tone (Bass) level
(0000=–15, 0128=0, 0255=+15)
1C
0000 ~ 0255
Send/read the tone (Treble) level
(0000=–15, 0128=0, 0255=+15)
1D
0000 ~ 0255
Send/read the Scan Speed
(0000=1, 0128=16, 0255=30)
1E
0000 ~ 0255
Send/read the Scan Delay
(0000=1s, 0128=16s, 0255=HOLD)
1F
0000 ~ 0255
Send/read the PRIO Interval
(0000=1s, 0128=8s, 0255=15s)
20
0000 ~ 0255
Send the RESUME TIME
(0000=0s, 0128=4s, 0255=HOLD)
15
01
00/01
Read noise or S-meter squelch status
(00=Close, 01=Open)
02
0000 ~ 0255
Read the S-meter level
(0000=S0, 0120=S9, 0241=S9+60dB)
03
Read the meter level in the
"AAAABBCC" Format:
AAAA= Absolute signal strength (in
0.1 steps)
BB= Plus or minus sign (00=+, 01=–)
CC=
Meter type (00=dBμ, 01=dBμ EMF,
02=dBm)
04
0000 ~ 0255
Read the center meter level
(0000= Left edge, 0128= Center,
0255= Right edge)
05
00/01
Read various squelch function’s
(including the tone squelch) status
(00=Close, 01=Open)
06
00/01
Read the S-AM SYNC Indicator
(00=Non-synchronous,
01=Synchronous)
07
00/01
Read the OVF indicator status