Page 4 highlights
Remote control DDCommand table Cmd. 00 01 02 03 04 05 06 07 08 Sub cmd. A0 09 0A 0B 0C 0D 0E 00 01 02 03 04 12 13 22 23 24 42 A0 AA Ax B0 B1 B2 D0 D1 D3 0F 10 11 12 10* Data See p. 9 See p. 9 See p. 9 See p. 9 See p. 9 See p. 9 See p. 9 0000 ~ 0199 0000 ~ 0102 See p. 9 01 ~ 09 00 ~ 09 10 ~ 12 00 01 02 03 04 05 06 07 08 09 10 11 Description Output the frequency data for transceive Output the receiving mode for transceive Read the band edge frequencies Read the receiving frequency Read the receiving mode Set the receiving frequency Select the receiving mode Select the VFO mode Select the Memory mode Select the Memory channel (0000 ~ 0099: Normal Memory channels/Scan Skip channels/Scan edges) (0000 ~ 0199: Auto Memory Write channels) Select the Memory group (0000 ~ 0099: Normal Memory channels 0100: Auto Memory Write channels 0101: Scan Skip channels 0102: Scan edges) Memory write mode Memory copy to VFO Memory clear Read offset frequency Set offset frequency Scan stop Programmed/memory scan start Programmed scan start ∂F scan start Auto Memory Write scan start Fine Programmed scan start Fine ∂F scan start Memory scan start Select memory scan start Mode Select scan start Priority scan start Set the Fix of ∂F frequency to OFF Set the Fix of ∂F frequency to ON Set/read the Fix range (x) of ∂F frequency (1=±5kHz, 2=±10kHz, 3=±20kHz, 4=±50kHz, 5=±100kHz, 6=±500kHz, 7=±1MHz) Set as non-select channel Set as select channel (If no selection is performed, the previously set number by CI-V is set after turning power ON, otherwise "1" is automatically set.) Set as select channel (01=SEL1, 02=SEL2, 03=SEL3, 04=SEL4, 05=SEL5, 06=SEL6, 07=SEL7, 08=SEL8, 09=SEL9) Set starting select memory channel for a select memory scan (00=ALL, 01=SEL1, 02=SEL2, 03=SEL3, 04=SEL4, 05=SEL5, 06=SEL6, 07=SEL7, 08=SEL8, 09=SEL9) Set Scan resume OFF Set Scan resume ON (PAUSE TIME=HOLD) Set Scan resume ON Read duplex setting (10=OFF, 11=DUP-, 12=DUP+) Set Simplex Set Duplex - Set Duplex + Send/read the tuning step OFF (in 10 Hz steps) Send/read the 100 Hz tuning step Send/read the 1 kHz tuning step Send/read the 2.5 kHz tuning step Send/read the 3.125 kHz tuning step Send/read the 5 kHz tuning step Send/read the 6.25 kHz tuning step Send/read the 8.33 kHz tuning step Send/read the 9 kHz tuning step Send/read the 10 kHz tuning step Send/read the 12.5 kHz tuning step Send/read the 20 kHz tuning step Cmd. Sub cmd. 10* 11* 12* 13 00 01 02 14* 01 02 03 06 07 08 09 0D 12 19 1B 1C 1D 1E 1F 20 15 01 02 03 04 05 06 07 Data 12 13 14 00 10 20 30 00 ~ 02 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 0000 ~ 0255 00/01 0000 ~ 0255 0000 ~ 0255 00/01 00/01 00/01 Description Send/read the 25 kHz tuning step Send/read the 100 kHz tuning step Send/read the programmable tuning step Send/read Attenuator OFF (0 dB) Send/read Attenuator (10 dB) Send/read Attenuator (20 dB) Send/read Attenuator (30 dB) Select antenna (only 10 kHz - 29.999999 MHz) (00=ANT1, 01=ANT2, 02=ANT3) Speech all parameters (Signal level + Frequency + Receiving mode) Speech frequency (Signal level + Frequency) Speech receiving mode LThe mode is announced after the ongoing speech. Send/read the AF gain level (0000=Minimum ~ 0255=Maximum) Send/read the RF gain level (0000=Minimum ~ 0255=Maximum) Send/read the squelch level (0000=Minimum ~ 0255=Maximum) Send/read the NR level (0000=0% ~ 0255=100%) Send/read the PBT1 position (0000=Narrow the upper edge, 0128=Center position, 0255=Narrow the lower edge) Send/read the PBT2 position (0000=Narrow the upper edge, 0128=Center position, 0255=Narrow the lower edge) Send/read CW pitch (0000=300 Hz, 0128=600 Hz, 0255=900 Hz) (in 5 Hz steps) Send/read the NOTCH position (0000=A lower position, 0128=Center position, 0255=A upper position) Send/read the NB level (0000=0% ~ 0255=100%) Send/read the LCD brightness (0000=0% ~ 0255=100%) Send/read the tone (Bass) level (0000=-15, 0128=0, 0255=+15) Send/read the tone (Treble) level (0000=-15, 0128=0, 0255=+15) Send/read the Scan Speed (0000=1, 0128=16, 0255=30) Send/read the Scan Delay (0000=1s, 0128=16s, 0255=HOLD) Send/read the PRIO Interval (0000=1s, 0128=8s, 0255=15s) Send the RESUME TIME (0000=0s, 0128=4s, 0255=HOLD) Read noise or S-meter squelch status (00=Close, 01=Open) Read the S-meter level (0000=S0, 0120=S9, 0241=S9+60dB) Read the meter level in the "AAAABBCC" Format: AAAA= Absolute signal strength (in 0.1 steps) BB= P lus or minus sign (00=+, 01=-) CC= M eter type (00=dBμ, 01=dBμ EMF, 02=dBm) Read the center meter level (0000= Left edge, 0128= Center, 0255= Right edge) Read various squelch function's (including the tone squelch) status (00=Close, 01=Open) Read the S-AM SYNC Indicator (00=Non-synchronous, 01=Synchronous) Read the OVF indicator status (00=OFF, 01=ON) 3