Remote control DDCommand table (Continued) Cmd. Sub cmd. 1A 05* 0143 0144 0145 0146 0147 0148 0149 0150 0151 0152 0153 0154 0155 0156 0157 0158 0159 0160 0161 0162 0163 0164 0165 0166 0167 0168 0169 0170 0171 0172 0173 0174 0175 Data See p. 10 See p. 10 Description Send/read the waveform outline color Send/read the scope waveform (Max hold) color See p. 10 Send/read the pointer color for the RX Marker See p. 10 Send/read the pointer color for the Peak Marker 00/01 Send/read the scope Water fall display (00=OFF, 01=ON) 00 ~ 02 Send/read the scope Waterfall speed (00=Slow, 01=Mid, 02=Fast) 00 ~ 02 00 ~ 07 00/01 Send/read the scope Waterfall height for the Expand scope screen (00=Small, 01=Mid, 02=Large) Send/read the signal level that the scope Waterfall displays a peak color (00=Grid 1, 01=Grid 2, 02=Grid 3, 03=Grid 4, 04=Grid 5, 05=Grid 6, 06=Grid 7, 07=Grid 8) Send/read the Waterfall Marker Autohide function setting (00=OFF, 01=ON) 00 ~ 60 00 ~ 80 00/01 00 ~ 02 00/01 Send/read the difference of amplitude between the peak signal and nearby signals (00=0 dB ~ 60=60 dB) Send/read the threshold level for the Peak signal detection (00=-80 dB ~ 80=0 dB) Send/read the spectrum waveform peek search type (00=Real time, 01=Max. Hold) Send/read the period of time of the Temporary Skip timer (00=5 minutes, 01=10 minutes, 02=15 minutes) Send/read the Skip function setting (00=OFF, 01=ON) 00 ~ 02 Send/read the Auto Memory Write Scan starting option (00=OFF, 01=Displays the dialog, 02=ON) 00/01 Send/read the SCAN screen display option (00=OFF, 01=ON) 00/01 00 ~ 03 See p. 10 00/01 00/01 Send/read the scan operation when MAIN DIAL is rotated (00=OFF, 01=Up/Down) Send/read the FSK FFT scope waveform averaging function setting (00=OFF, 01=2, 02=3, 03=4) Send/read the color of the FSK FFT scope waveform (000000000000 ~ 025502550255) Send/read the FSK Letter Code Decoding function setting (00=OFF, 01=ON) Send/read the FSK decoder new line code (00=CR,LF,CR+LF, 01=CR+LF) 00/01 Send/read the FSK log time stamp (Time) (00=Local, 01=UTC) 00/01 See p. 10 Send/read the FSK log time stamp (Frequency) (00=OFF, 01=ON) Send/read the text font color for received FSK signal See p. 10 Send/read the text font color for the time stamp 00/01 Send/read FSK log function setting (00=OFF, 01=ON) 00/01 Send/read FSK log file type (00=Text, 01=HTML) 00/01 Send/read the FSK RX frequency (00=Mark (Space), 01=Mark/Space center) 00 ~ 03 Send/read the FSK mark frequency (00=1275, 01=1500, 02=1615, 03=2125) 00 ~ 04 Send/read the FSK shift width (00=170, 01=200, 02=425, 03=800, 04=850) 00/01 Send/read the recording setting (00=Always, 01=Squelch Auto) 00/01 Send/read the File Split function setting (00=OFF, 01=ON) 00 ~ 03 Send/read the player skip time (00=3 seconds, 01=5 seconds, 02=10 seconds, 03=30 seconds) 7 Cmd. 1A 1B* Sub cmd. 05* 0176 0177 0178 0179 0180 0181 0182 07* 08 09* 0A 0B 00 01 02 03 04 05 0C 00* 01 02 0D 00* 01 02 0E 0F 10 11 01 02 03 07 08 09 0A 0B 0C 0D 0E Data Description 00 ~ 09 Send/read the Noise Blanker depth (Noise reducing level) (00=1 ~ 09=10) 0000 ~ 0255 Send/read the Noise Blanker width (Blanking period) (0000=1 ~ 0255=100) 00/01 Send/read the Memory group type (00=Current group, 01=All groups) 00/01 Send/read the scanning Memory group type (00=Current group, 01=All groups) 00 ~ 03 Send/read the meter type (00=S, 01=dBμ, 02=dBμ EMF, 03=dBm) 00/01 Selects the mute state for the Encryption function in the NXDN mode (00=OFF, 01=ON) 00 ~ 02 00/01 Send/read the full keyboard layout type (00=Japanese, American and English 01=German, 02=French) Send/read the IP+ function (00=OFF, 01=ON) Read the power supply voltage (You can remotely check the power supply voltage in 0.1 V steps.) 00/01 Send/read the connection status of NTP server (00=Stop, 01=Start) 00 ~ 02 Read the date and time update result (00=Updating, 01=Succeed, 02=Failed) See pp. 14 ~ 16 Start a Programmable Scan (Remote) Cancel the Programmable Scan mute (Remote) See pp. 16 ~ 18 Start a Memory Scan (Remote) See p. 18 Send the scanning data (Remote) Resume the scan (Remote) Cancel the scan (Remote) 00/01 Send/read the Scan status (Remote) (00= transceive OFF, 01=transceive ON) 00 ~ 03 Output the scan status for transceive (Remote) (00=Scan is stopped, 01=Scanning, 02=Scan is stopped on a signal (Busy) 03=Scan is stopped on a signal (Not busy)) 00 ~ 02 Read the scan status (00=Stopped, 01=Scanning, 02=Busy stop) 00/01 Send/read the scanning channel setting (00= transceive OFF, 01=transceive ON) Output the scanning channel for transceive (Serial number (1 byte) + Channel number (1 byte)) Read the scanning channel (Serial number (1 byte) + Channel number (1 byte)) If the scan is not executed by the command "1A 0B 02," "FF" is returned. Read the bad edge count (Number of edge data (1 byte)) See p. 9 Read the band edge frequency Read the meter readout (Format= AAAABBCC: AAAA= signal level (000.0 ~ 999.9)* BB= Plus or minus (00=+, 01=-) CC= Meter type (00=dBµ, 01=dBµ EMF, 02=dBm)) *When the value is "123.4," "1234" is returned. Read the CI-V connection terminal (00=[REMOTE], 01=[USB] (rear), 02=[USB] (front), 03=[LAN]) See p. 18 Send/read the TSQL tone frequency See p. 18 Send/read the DTCS code 000 ~ FFF Send/read the P25 NAC (First 4 bits in each byte are fixed to "0.") 00 ~ 99 Send/read the D-STAR CSQL code 001 ~ 255 Send/read the dPMR COM ID 00 ~ 63 Send/read the dPMR CC 00 ~ 63 Send/read the NXDN RAN 001 ~ 511 Send/read the DCR UC 00001 ~ 32767 Send/read the dPMR scrambler key 00001 ~ 32767 Send/read the NXDN encryption key 00001 ~ 32767 Send/read the DCR encryption key

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

Cmd.
Sub cmd.
Data
Description
1A
05*
0143
See p. 10
Send/read the waveform outline color
0144
See p. 10
Send/read the scope waveform (Max
hold) color
0145
See p. 10
Send/read the pointer color for the RX
Marker
0146
See p. 10
Send/read the pointer color for the Peak
Marker
0147
00/01
Send/read the scope Water fall display
(00=OFF, 01=ON)
0148
00 ~ 02
Send/read
the scope Waterfall speed
(00=Slow, 01=Mid, 02=Fast)
0149
00 ~ 02
Send/read the scope Waterfall height for
the Expand scope screen
(00=Small, 01=Mid, 02=Large)
0150
00 ~ 07
Send/read the signal level that the
scope Waterfall displays a peak color
(00=Grid 1, 01=Grid 2, 02=Grid 3,
03=Grid 4, 04=Grid 5, 05=Grid 6,
06=Grid 7, 07=Grid 8)
0151
00/01
Send/read the Waterfall Marker Auto-
hide function setting
(00=OFF, 01=ON)
0152
00 ~ 60
Send/read the difference of amplitude
between the peak signal and nearby
signals
(00=0 dB ~ 60=60 dB)
0153
00 ~ 80
Send/read the threshold level for the
Peak signal detection
(00=–80 dB ~ 80=0 dB)
0154
00/01
Send/read the spectrum waveform peek
search type
(00=Real time, 01=Max. Hold)
0155
00 ~ 02
Send/read the period of time of the
Temporary Skip timer
(00=5 minutes, 01=10 minutes,
02=15 minutes)
0156
00/01
Send/read the Skip function setting
(00=OFF, 01=ON)
0157
00 ~ 02
Send/read the Auto Memory Write Scan
starting option
(00=OFF, 01=Displays the dialog, 02=ON)
0158
00/01
Send/read the SCAN screen display option
(00=OFF, 01=ON)
0159
00/01
Send/read the scan operation when
MAIN DIAL is rotated
(00=OFF, 01=Up/Down)
0160
00 ~ 03
Send/read the FSK FFT scope
waveform averaging function setting
(00=OFF, 01=2, 02=3, 03=4)
0161
See p. 10
Send/read the color of the FSK FFT
scope waveform
(000000000000 ~ 025502550255)
0162
00/01
Send/read the FSK Letter Code
Decoding function setting
(00=OFF, 01=ON)
0163
00/01
Send/read the FSK decoder new line code
(00=CR,LF,CR+LF, 01=CR+LF)
0164
00/01
Send/read the FSK log time stamp (Time)
(00=Local, 01=UTC)
0165
00/01
Send/read the FSK log time stamp
(Frequency)
(00=OFF, 01=ON)
0166
See p. 10
Send/read the text font color for
received FSK signal
0167
See p. 10
Send/read the text font color for the
time stamp
0168
00/01
Send/read FSK log function setting
(00=OFF, 01=ON)
0169
00/01
Send/read FSK log file type
(00=Text, 01=HTML)
0170
00/01
Send/read the FSK RX frequency
(00=Mark (Space), 01=Mark/Space center)
0171
00 ~ 03
Send/read the FSK mark frequency
(00=1275, 01=1500, 02=1615, 03=2125)
0172
00 ~ 04
Send/read the FSK shift width
(00=170, 01=200, 02=425, 03=800, 04=850)
0173
00/01
Send/read the recording setting
(00=Always, 01=Squelch Auto)
0174
00/01
Send/read the File Split function setting
(00=OFF, 01=ON)
0175
00 ~ 03
Send/read the player skip time
(00=3 seconds, 01=5 seconds, 02=10
seconds, 03=30 seconds)
Cmd.
Sub cmd.
Data
Description
1A
05*
0176
00 ~ 09
Send/read the Noise Blanker depth
(Noise reducing level)
(00=1 ~ 09=10)
0177
0000 ~ 0255
Send/read the Noise Blanker width
(Blanking period)
(0000=1 ~ 0255=100)
0178
00/01
Send/read the Memory group type
(00=Current group, 01=All groups)
0179
00/01
Send/read the scanning Memory group type
(00=Current group, 01=All groups)
0180
00 ~ 03
Send/read the meter type
(00=S, 01=dBμ, 02=dBμ EMF, 03=dBm)
0181
00/01
Selects the mute state for the Encryption
function in the NXDN mode
(00=OFF, 01=ON)
0182
00 ~ 02
Send/read the full keyboard layout type
(00=Japanese, American and English
01=German, 02=French)
07*
00/01
Send/read the IP
function
(00=OFF, 01=ON)
08
Read the power supply voltage
(You can remotely check the power
supply voltage in 0.1 V steps.)
09*
00/01
Send/read the connection status of NTP server
(00=Stop, 01=Start)
0A
00 ~ 02
Read the date and time update result
(00=Updating, 01=Succeed, 02=Failed)
0B
00
See pp. 14 ~ 16
Start a Programmable Scan (Remote)
01
Cancel the Programmable Scan mute
(Remote)
02
See pp. 16 ~ 18
Start a Memory Scan (Remote)
03
See p. 18
Send the scanning data (Remote)
04
Resume the scan (Remote)
05
Cancel the scan (Remote)
0C
00*
00/01
Send/read the Scan status (Remote)
(00= transceive OFF, 01=transceive ON)
01
00 ~ 03
Output the scan status for transceive
(Remote)
(00=Scan is stopped,
01=Scanning,
02=Scan is stopped on a signal (Busy)
03=
Scan is stopped on a signal (Not busy))
02
00 ~ 02
Read the scan status
(00=Stopped,
01=Scanning,
02=Busy stop)
0D
00*
00/01
Send/read the scanning channel setting
(00= transceive OFF, 01=transceive ON)
01
Output the scanning channel for transceive
(Serial number (1 byte) + Channel
number (1 byte))
02
Read the scanning channel
(Serial number (1 byte) + Channel
number (1 byte))
If the scan is not executed by the
command "1A 0B 02," "FF" is returned.
0E
Read the bad edge count
(Number of edge data (1 byte))
0F
See p. 9
Read the band edge frequency
10
Read the meter readout
(Format= AAAABBCC:
AAAA= signal level (000.0 ~ 999.9)*
BB= Plus or minus (00=+, 01=–)
CC= Meter type
(00=dBµ, 01=dBµ EMF, 02=dBm))
*When the value is "123.4," "1234" is returned.
11
Read the CI-V connection terminal
(00=[REMOTE], 01=[USB] (rear),
02=[USB] (front), 03=[LAN])
1B*
01
See p. 18
Send/read the TSQL tone frequency
02
See p. 18
Send/read the DTCS code
03
000 ~ FFF
Send/read the P25 NAC
(First 4 bits in each byte are fixed to "0.")
07
00 ~ 99
Send/read the D-STAR CSQL code
08
001 ~ 255
Send/read the dPMR COM ID
09
00 ~ 63
Send/read the dPMR CC
0A
00 ~ 63
Send/read the NXDN RAN
0B
001 ~ 511
Send/read the DCR UC
0C
00001 ~ 32767
Send/read the dPMR scrambler key
0D
00001 ~ 32767
Send/read the NXDN encryption key
0E
00001 ~ 32767
Send/read the DCR encryption key
D
Command table (Continued)
Remote control
7