Intermec PX6i Intermec Direct Protocol 8.60 Programmer's Reference Manual - Page 38

Specify Bar Code Height, BARHEIGHT, BARRATIO, BARMAG

Page 38 highlights

Chapter 3-Label Design UPC-D2 UPC-D3 UPC-D4 UPC-D5 UPC-E UPC-E Composite with CC-A or CC-B UPC Shipping Container Code "UPCD2" "UPCD3" "UPCD4" "UPCD5" "UPCE" "UPCE-CC" "UPCSCC" Specify Bar Code Height The height of the bars that make up the bar code can be specified using the BARHEIGHT instruction. BARHEIGHT | BH Default: Reset to default by: is the height of the bars in dots. 100 PRINTFEED (PF) Specify Bar Code Ratio The ratio between the wide and the narrow bars can be set using a BARRATIO instruction. BARRATIO | BR , Default: Reset to default by: is a relational factor wide bars vs narrow bars is a relational factor narrow bars vs wide bars 3:1 PRINTFEED (PF) Specify Bar Code Magnification The magnification of the bar code and the bar code ratio decide the actual thickness of the bars. For example, if BARRATIO is 3:1 and BARMAG is 2, then the wide bars will be 6 dots thick (3×2) and the narrow bars will be 2 dots (1×2). Magnification also affects interpretations that are integrated in the code, for example EAN and UPC codes. BARMAG | BM Default: Reset to default by: is the enlargement of the bar code pattern. 2 PRINTFEED (PF) 30 Intermec Direct Protocol v.8.60-Programmer's Reference Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134

30
Intermec Direct Protocol v.8.60—Programmer’s Reference Manual
Chapter 3—Label Design
UPC-D2
"UPCD2"
UPC-D3
"UPCD3"
UPC-D4
"UPCD4"
UPC-D5
"UPCD5"
UPC-E
"UPCE"
UPC-E Composite with CC-A or CC-B
"UPCE-CC"
UPC Shipping Container Code
"UPCSCC"
Specify Bar Code Height
°e height of the bars that make up the bar code can be specified using
the
BARHEIGHT
instruction.
BARHEIGHT | BH <height>
<height>
is the height of the bars in dots.
Default:
100
Reset to default by:
PRINTFEED (PF)
Specify Bar Code Ratio
°e ratio between the wide and the narrow bars can be set using a
BARRATIO
instruction.
BARRATIO | BR <wide bars>,<narrow bars>
<wide bars>
is a relational factor wide bars vs narrow bars
<narrow bars>
is a relational factor narrow bars vs wide bars
Default:
3:1
Reset to default by:
PRINTFEED (PF)
Specify Bar Code Magnification
°e magnification of the bar code and the bar code ratio decide the
actual thickness of the bars. For example, if
BARRATIO
is 3:1 and
BARMAG
is 2, then the wide bars will be 6 dots thick (3×2) and the narrow bars
will be 2 dots (1×2). Magnification also affects interpretations that are
integrated in the code, for example EAN and UPC codes.
BARMAG | BM <magnification>
<magnification>
is the enlargement of the bar code pattern.
Default:
2
Reset to default by:
PRINTFEED (PF)