Konica Minolta A00F011 Service Manual - Page 123

Ozone ventilation fan motor, Duplex cooling fan motor control

Page 123 highlights

magicolor 4650EN magicolor 4650DN 22. Miscellaneous Theory of operation Ver.1.0 Nov. 2007 C. Ozone ventilation fan motor • At the start of a warm-up cycle • During a print cycle • During when the image stabilization control is performed • For the period of time when the thermistor/3 provided in the print head detects the tem- perature of predetermined degrees or more • A predetermined period of time elapses after a warm-up cycle is completed • At the end of a print cycle • During the power save mode. The motor is not, however, stopped for a predetermined period of time after a predrive is complete. • A malfunction occurs, but not when an error occurs. D. Duplex cooling fan motor control • For the period of time when the thermistor provided in the print head detects the temper- ature of predetermined degrees or more • For the period of time that begins when a print cycle starts and ends when a predeter- mined period of time elapses after the print cycle has been completed. • During when the image stabilization control is performed • During the power save mode. • During the light door open. • During the warm-up cycle. • A print cycle is being carried out using transparency • A malfunction occurs, but not when an error occurs. Composition/Operation 88

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146

22. Miscellaneous
Theory of operation Ver.1.0 Nov. 2007
88
magicolor 4650EN
magicolor 4650DN
C
om
p
o
siti
o
n/Ope
ra
ti
o
n
C.
Ozone ventilation fan motor
<Full speed rotation conditions>
At the start of a warm-up cycle
During a print cycle
During when the image stabilization control is performed
For the period of time when the thermistor/3 provided in the print head detects the tem-
perature of predetermined degrees or more
<Stop conditions>
A predetermined period of time elapses after a warm-up cycle is completed
At the end of a print cycle
During the power save mode. The motor is not, however, stopped for a predetermined
period of time after a predrive is complete.
<Forced stop condition>
A malfunction occurs, but not when an error occurs.
D.
Duplex cooling fan motor control
<Full speed rotation conditions>
For the period of time when the thermistor provided in the print head detects the temper-
ature of predetermined degrees or more
For the period of time that begins when a print cycle starts and ends when a predeter-
mined period of time elapses after the print cycle has been completed.
During when the image stabilization control is performed
<Stop conditions>
During the power save mode.
During the light door open.
During the warm-up cycle.
A print cycle is being carried out using transparency
<Forced stop condition>
A malfunction occurs, but not when an error occurs.