Konica Minolta A00F011 Service Manual - Page 145
Media reference position adjustment mechanism, Media misfeed detection control
View all Konica Minolta A00F011 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 145 highlights
Lower feeder unit 4. Operations Theory of operation Ver. 1.0 Nov. 2007 4.1.10 Media reference position adjustment mechanism • The edge guide plate can be moved to allow the print start reference position for the media to be adjusted. 1. Through a hole in the media lift plate on top of the tray, loosen two screws that secure the edge guide plate. 2. Accessing the tray from its bottom surface, loosen two screws that secure the reference position adjusting plate. 3. Slide the reference position adjusting plate as necessary as indicated on the scale. 4. From the bottom surface of the tray, tighten the two screws that secure the reference position adjusting plate. 5. Through the hole in the media lift plate on top of the tray, tighten the two screws that secure the edge guide plate. Media lift plate Edge guide plate fixing screws 4138to2125c0 Reference position adjusting plate Adjustment scale Composition/Operation 4138to2123c0 Reference position adjusting plate fixing screws 4.1.11 Media misfeed detection control • If the media feed sensor is not activated within a predetermined period of time after a media feed sequence has been started, the main body determines that there is a media misfeed. It then displays a media misfeed message on the panel. • The media misfeed display can be reset by opening and closing any door. 10