No mechanism is provided for detecting a media near empty condition. The media sup
View all Konica Minolta A00F011 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 142 highlights
Lower feeder unit Composition/Operation Theory of operation Ver. 1.0 Nov. 2007 4. Operations 4.1.5 Media supply level detection control • There is a window in the front cover of the cassette for indicating the media supply level. • When the media lift plate goes up, a red lever appears in the window. The lower the level of the media stack in the tray, the more red that is visible. Media lift plate Lever indicator indicating the media supply level A media empty condition Lever 4138to2117c0 4138to2118c0 When media is loaded 4.1.6 Media empty condition detection control • The media empty message is displayed on the panel when the empty sensor actuator unblocks the media empty sensor. • No mechanism is provided for detecting a media near empty condition. The media supply level indicator serves this purpose. When media is loaded Actuator Media empty sensor (PS1) Media A media empty condition Media lift plate 4138to2119c0 7