Konica Minolta ScanDIVA ScanDIVA User Guide - Page 54
Position
View all Konica Minolta ScanDIVA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 54 highlights
ScanDIVA User's Guide 6 The histogram and the average of the R, G, B values of the selected area is displayed. Adjust the tone curve so that the value of the "G" will be within the following range. Gray Scale Position A: Position M: Position 19: Acceptable Range 242 ± 4 104 ± 4 12 ± 4 NOTE ! Adjust the selected area with the mouse. The value will be changed to that of destination's area. If no area is selected, the entire image area will be adjusted. 7 If you want to adjust the tone curve, check "Detail & Adjustment" and select "8. Tone Curve" in the pull-down list and then click "Run". 3-24
ScanDIVA User’s Guide
3-24
6
The histogram and the average of the R, G, B values of the selected area is
displayed.
Adjust the tone curve so that the value of the
“G”
will be within the following
range.
Gray Scale
Acceptable Range
Position A:
242 ± 4
Position M:
104 ± 4
Position 19:
12 ± 4
NOTE
!
Adjust the selected area with the mouse. The value will be
changed to that of destination’s area.
If no area is selected, the entire image area will be adjusted.
7
If you want to adjust the tone curve, check “Detail & Adjustment” and select
“8. Tone Curve” in the pull-down list and then click “Run”.