LG KM710 Service Manual - Page 78
Slide Up/Down Trouble Shooting
View all LG KM710 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 78 highlights
4. Trouble Shooting 4.9 Slide Up/Down Trouble Shooting Slide Operation scheme is shown below. SLIDE SWITCH VRIO C102 1u PGND 5 BU52031NVX U100 4 3 VDD NC 1 OUT GND 2 SLIDE C103 0.01u Block Diagram (Folder On/Off) Slide Magnet Hall Effect Switch (U100) High Low 1.8 V 0 V DBB(U103) GPIO 57 (R10 pin) 4.9.1 Slide Operation(ON/OFF) - There is a magnet to detect the slide status, opened or closed. - If a magnet is down to the hall-effect switch(U100), the voltage at pin 1 of U100 goes to 0V. Otherwise, 1.8V - This Slide signal is delivered to DBB, and the status of Slide is reported. Slide Signal Status L : Down (Magnetized) => Slide Down H : Up (Not magnetized) => Slide Up Copyright © 2008 LG Electronics. Inc. All right reserved. Only for training and service purposes - 79 - LGE Internal Use Only