LG LMCN185HV Installation Instructions - Page 14

Remove the spacer.

Page 14 highlights

Installation 9. Wrap the insulation material around the connecting portion. 1) Overlap the connection pipe insulation and the indoor unit pipe heat insulation material. Bind them together with vinyl tape so that there is no gap. 2) Wrap the area which accommodates the rear piping housing section with vinyl tape. 3) Bundle the piping and drain hose together by wrapping them with vinyl tape over the range within which they fit into the rear piping housing section. Plastic bands Insulation material Connection pipe Vinyl tape (wide) Connecting cable Wrap with vinyl tape Pipe Indoor unit piping Vinyl tape(narrow) Drain hose Pipe Vinyl tape(narrow) Wrap with vinyl tape(wide) 10. Reroute the pipings and the drain hose across the back of the chassis. 11. Indoor unit installation 1) Remove the spacer. 2) Ensure that the hooks are properly seated on the installation plate by moving it left and right. 3) Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots(clicking sound). Piping for passage through piping hole Connecting cable Drain hose 14 Multi Air Conditioner

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137

14
Multi Air Conditioner
Installation
9. Wrap the insulation material around the
connecting portion.
1) Overlap the connection pipe insulation and
the indoor unit pipe heat insulation
material. Bind them together with vinyl
tape so that there is no gap.
2) Wrap the area which accommodates the
rear piping housing section with vinyl tape.
3) Bundle the piping and drain hose together
by wrapping them with vinyl tape over the
range within which they fit into the rear
piping housing section.
10. Reroute the pipings and the drain hose
across the back of the chassis.
11. Indoor unit installation
1) Remove the spacer.
2) Ensure that the hooks are properly seated
on the installation plate by moving it left
and right.
3) Press the lower left and right sides of the
unit against the installation plate until the
hooks engage into their slots(clicking
sound).
Plastic bands
Insulation material
Vinyl tape(narrow)
Connection
pipe
Connecting cable
Indoor
unit piping
Pipe
Vinyl tape
(wide)
Wrap with vinyl tape
Drain hose
Vinyl tape(narrow)
Pipe
Wrap with
vinyl tape(wide)
Piping for