Wired remote controller switch information
View all LG LMCN185HV manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
ENGLISH Wired remote controller switch information Installation Group Control 2 1 SW±GR Group control switch 1. For individual control/Master use 2. For group control/Slave use Ceiling Height/Default E.S.P 3 2 1 S/W 1 SW±HI Select Product 2 1 SW±PD Ceiling height selection switch 1. Low ceiling 2. Standard ceiling 3. High ceiling Product selection switch 1. Cooling Only product 2. Heat Pump product Room Temp. Sensing 321 SW±TH Indoor temperature sensor selection switch 1. Use the temperature sensor on the remote controller. 2. Use the temperature sensor on the product. 3. Use the sensors on the product and remote controller. • When changing the product selection switch and group control switch, the power must be reconnected to reflect the changes. • The central control could operate inappropriately depends on indoor unit type, when the remote controller is set as slave. Installation Manual 21