Lantronix EDS8PS EDS - Command Reference - Page 186
used to enter, Prevents the user-defined serial boot string from being
![]() |
View all Lantronix EDS8PS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 186 highlights
default flow control default interface default parity default protocol default stop bits default threshold default xoff char default xon char exit flow control hardware flow control none flow control software gap timer interface rs232 interface rs485 full-duplex interface rs485 half-duplex kill session line lpd name no clear line counters no command mode no command mode serial string no command mode signon message no gap timer no name parity even parity none parity odd protocol lpd protocol lpd or tunnel protocol modbus ascii protocol modbus rtu protocol none protocol tunnel reassert show show command mode EDS Command Reference 5: Commands and Levels Restores the default of no flow control. Restores the default interface type to this line. Restores the default of no parity. Restores the default protocol on the line. Restores the default of one stop bit. Restores the factory default threshold. Restores the default xoff character on this line. Restores the default xon character on this line. Exits to the enable level Uses hardware (RTS/CTS) flow control on the line. Does not provide flow control on the line. Uses software (xon/xoff characters) flow control on the line. Sets the gap timer in milliseconds. If some data has been received, it will be forwarded after this time since the last character. Sets the line interface to RS232. Sets the line interface to RS485 in full-duplex mode. Sets the line interface to RS485 in half-duplex mode. Kills command mode session on the Line Enters the line level. = number of the line (serial port) to be configured. Enters the configure lpd level. = number of the line (lpd serial port) to be configured. Sets the name for this line. Restores the serial counters to the aggregate values. Disables command mode for the current line. Prevents the user-defined serial boot string from being used to enter command mode in the CLI. Clears the signon message displayed at boot time and when entering command mode. Removes the gap timer, so forwarding depends on the line speed. Removes the name of this line. Uses a parity bit on the line for even parity. Does not use a parity bit on the line. Uses a parity bit on the line for odd parity. Applies Line Printer Daemon (LPD) protocol on the line. Applies LPD or tunnel protocol on the line. Applies Modbus ASCII protocol on the line. Applies Modbus RTU protocol on the line. Uses no protocol on the line. Applies tunnel protocol on the line. Asserts line status with current configured values. Displays the current status. Shows the command mode settings for the current line. 186
![](/manual_guide/products/lantronix-eds8pr-eds-command-reference-32f14d3/186.png)