Lantronix EDS8PS EDS - Command Reference - Page 188
Sets the line interface to RS232., interface rs232
![]() |
View all Lantronix EDS8PS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 188 highlights
command mode signon message command mode signon message binary command mode wait time configure current settings data bits 7 data bits 8 default baud rate default data bits default flow control default interface default parity default protocol default stop bits default threshold default xoff char default xon char exit flow control hardware flow control none flow control software gap timer interface rs232 interface rs485 full-duplex interface rs485 half-duplex kill session line lpd name no clear line counters no command mode no command mode serial string no command mode signon message EDS Command Reference 5: Commands and Levels Within [] use binary decimal up to 255 or hex up to 0xFF. Sets an ASCII sign-on message that is sent from the serial port when the device boots and when the line is in command mode. = text. Sets a binary sign-on message that is sent from the serial port when the device boots and when the line is in command mode. = string that may contain binary characters. Within [] use binary decimal up to 255 or hex up to 0xFF. Sets boot-up wait time for command mode serial string. = wait time. Configures line with the current value of settings. Uses seven bits for data on the line. Uses eight bits for data on the line. Restores the default speed of 9600 bits per second. Restores the default of eight data bits. Restores the default of no flow control. Restores the default interface type to this line. Restores the default of no parity. Restores the default protocol on the line. Restores the default of one stop bit. Restores the factory default threshold. Restores the default xoff character on this line. Restores the default xon character on this line. Exits to the enable level Uses hardware (RTS/CTS) flow control on the line. Does not provide flow control on the line. Uses software (xon/xoff characters) flow control on the line. Sets the gap timer in milliseconds. If some data has been received, it will be forwarded after this time since the last character. Sets the line interface to RS232. Sets the line interface to RS485 in full-duplex mode. Sets the line interface to RS485 in half-duplex mode. Kills command mode session on the Line Enters the line level. = number of the line (serial port) to be configured. Enters the configure lpd level. = number of the line (lpd serial port) to be configured. Sets the name for this line. Restores the serial counters to the aggregate values. Disables command mode for the current line. Prevents the user-defined serial boot string from being used to enter command mode in the CLI. Clears the signon message displayed at boot time and when entering command mode. 188
![](/manual_guide/products/lantronix-eds8pr-eds-command-reference-32f14d3/188.png)