Lantronix EDS8PS EDS - Command Reference - Page 191

Shows the command mode settings for the current line., show command mode

Page 191 highlights

interface rs485 half-duplex kill session line lpd name no clear line counters no command mode no command mode serial string no command mode signon message no gap timer no name parity even parity none parity odd protocol lpd protocol lpd or tunnel protocol modbus ascii protocol modbus rtu protocol none protocol tunnel reassert show show command mode show history show line show statistics state disable state enable stop bits 1 stop bits 2 terminal terminal network threshold tunnel write EDS Command Reference 5: Commands and Levels Sets the line interface to RS485 in half-duplex mode. Kills command mode session on the Line Enters the line level. = number of the line (serial port) to be configured. Enters the configure lpd level. = number of the line (lpd serial port) to be configured. Sets the name for this line. Restores the serial counters to the aggregate values. Disables command mode for the current line. Prevents the user-defined serial boot string from being used to enter command mode in the CLI. Clears the signon message displayed at boot time and when entering command mode. Removes the gap timer, so forwarding depends on the line speed. Removes the name of this line. Uses a parity bit on the line for even parity. Does not use a parity bit on the line. Uses a parity bit on the line for odd parity. Applies Line Printer Daemon (LPD) protocol on the line. Applies LPD or tunnel protocol on the line. Applies Modbus ASCII protocol on the line. Applies Modbus RTU protocol on the line. Uses no protocol on the line. Applies tunnel protocol on the line. Asserts line status with current configured values. Displays the current status. Shows the command mode settings for the current line. Displays the last 20 commands entered during the current CLI session. Displays the current configuration. Shows the line statistics. Disables the line so data cannot be sent/received. Enables the line so data can be sent/received. Uses one stop bit after data on the line. Uses two stop bits after data on the line. Enters the configure-terminal level. = number of the terminal line (serial port) to be configured. Enters the configure-terminal level for the network. Sets the threshold in bytes. After this many bytes are received, they are forwarded without delay. Enters the tunnel level. = number of the tunnel line (serial port) to be configured. Stores the current configuration in permanent memory. 191

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221

5:
Commands and Levels
EDS Command Reference
191
interface rs485 half-duplex
Sets the line interface to RS485 in half-duplex mode.
kill session
Kills command mode session on the Line
line
<line>
Enters the line level.
<line> = number of the line (serial port) to be configured.
lpd
<line>
Enters the configure lpd level.
<line> = number of the line (lpd serial port) to be
configured.
name
<text>
Sets the name for this line.
no clear line counters
Restores the serial counters to the aggregate values.
no command mode
Disables command mode for the current line.
no command mode serial string
Prevents the user-defined serial boot string from being
used to enter
command mode in the CLI.
no command mode signon message
Clears the signon message displayed at boot time and
when entering
command mode.
no gap timer
Removes the gap timer, so forwarding depends on the
line speed.
no name
Removes the name of this line.
parity even
Uses a parity bit on the line for even parity.
parity none
Does not use a parity bit on the line.
parity odd
Uses a parity bit on the line for odd parity.
protocol lpd
Applies Line Printer Daemon (LPD) protocol on the line.
protocol lpd or tunnel
Applies LPD or tunnel protocol on the line.
protocol modbus ascii
Applies Modbus ASCII protocol on the line.
protocol modbus rtu
Applies Modbus RTU protocol on the line.
protocol none
Uses no protocol on the line.
protocol tunnel
Applies tunnel protocol on the line.
reassert
Asserts line status with current configured values.
show
Displays the current status.
show command mode
Shows the command mode settings for the current line.
show history
Displays the last 20 commands entered during the current
CLI session.
show line
Displays the current configuration.
show statistics
Shows the line statistics.
state disable
Disables the line so data cannot be sent/received.
state enable
Enables the line so data can be sent/received.
stop bits 1
Uses one stop bit after data on the line.
stop bits 2
Uses two stop bits after data on the line.
terminal
<line>
Enters the configure-terminal level.
<line> = number of the terminal line (serial port) to be
configured.
terminal network
Enters the configure-terminal level for the network.
threshold
<bytes>
Sets the threshold in bytes. After this many bytes are
received, they are
forwarded without delay.
tunnel
<line>
Enters the tunnel level.
<line> = number of the tunnel line (serial port) to be
configured.
write