Lantronix EDS8PS EDS - Command Reference - Page 197

lpd 4 config-lpd:4 level commands, Redirects serial output back to the line.

Page 197 highlights

show statistics soj disable soj enable soj text binary soj text set terminal terminal network test print tunnel write lpd 4 (config-lpd:4) level commands banner disable banner enable binary disable binary enable capture disable capture enable clrscrn convert newline disable convert newline enable eoj disable eoj enable eoj text binary eoj text set EDS Command Reference 5: Commands and Levels CLI session. Displays statistics and status information for this lpd line. Disables sending the start-of-job string after each print job. Enables sending the start-of-job string after each print job. Sets the start-of-job text allowing for binary characters. = string in binary format that will be sent to the printer at the beginning of each print job. Within [] use binary decimal up to 255 or hex up to 0xFF. Sets the start-of-job text. = ascii string that will be sent to the printer at the beginning of each print job. Enters the configure-terminal level. = number of the terminal line (serial port) to be configured. Enters the configure-terminal level for the network. Prints lines of text directly to the lpd line. = number of lines to print. Enters the tunnel level. = number of the tunnel line (serial port) to be configured. Stores the current configuration in permanent memory. Disables printing banner for all print jobs. Only print the banner when a job requests it. Enables printing banner for all print jobs. Treats print job as ascii text. Filters out all non-ascii characters and certain control characters. Treats print job as binary. Sends data byte-for-byte to the printer. Redirects serial output back to the line. Redirects serial output from the line to this CLI session. Clears the screen. Disables converting single new line and carriage return characters to DOS-style line endings. Enables converting single new line and carriage return characters to DOS-style line endings. If characters are already in DOS line-ending order, they are not converted. Disables sending the end-of-job string after each print job. Enables sending the end-of-job string after each print job. Sets the end-of-job text allowing for binary characters. = string in binary format that will be sent to the printer at the end of each print job. Within [] use binary decimal up to 255 or hex up to 0xFF. Sets the end-of-job text. = ascii string that will be sent to the printer at the 197

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221

5:
Commands and Levels
EDS Command Reference
197
CLI session.
show statistics
Displays statistics and status information for this lpd line.
soj disable
Disables sending the start-of-job string after each print
job.
soj enable
Enables sending the start-of-job string after each print job.
soj text binary
<binary>
Sets the start-of-job text allowing for binary characters.
<binary> = string in binary format that will be sent to the
printer at the
beginning of each print job.
Within [] use binary decimal up to 255 or hex up to 0xFF.
soj text set
<text>
Sets the start-of-job text.
<text> = ascii string that will be sent to the printer at the
beginning of
each print job.
terminal
<line>
Enters the configure-terminal level.
<line> = number of the terminal line (serial port) to be
configured.
terminal network
Enters the configure-terminal level for the network.
test print
<number of lines>
Prints lines of text directly to the lpd line.
<number of lines> = number of lines to print.
tunnel
<line>
Enters the tunnel level.
<line> = number of the tunnel line (serial port) to be
configured.
write
Stores the current configuration in permanent memory.
lpd 4 (config-lpd:4) level commands
banner disable
Disables printing banner for all print jobs. Only print the
banner when a
job requests it.
banner enable
Enables printing banner for all print jobs.
binary disable
Treats print job as ascii text. Filters out all non-ascii
characters and
certain control characters.
binary enable
Treats print job as binary. Sends data byte-for-byte to the
printer.
capture disable
Redirects serial output back to the line.
capture enable
Redirects serial output from the line to this CLI session.
clrscrn
Clears the screen.
convert newline disable
Disables converting single new line and carriage return
characters to
DOS-style line endings.
convert newline enable
Enables converting single new line and carriage return
characters to
DOS-style line endings. If characters are already in DOS
line-ending order,
they are not converted.
eoj disable
Disables sending the end-of-job string after each print job.
eoj enable
Enables sending the end-of-job string after each print job.
eoj text binary
<binary>
Sets the end-of-job text allowing for binary characters.
<binary> = string in binary format that will be sent to the
printer at the
end of each print job.
Within [] use binary decimal up to 255 or hex up to 0xFF.
eoj text set
<text>
Sets the end-of-job text.
<text> = ascii string that will be sent to the printer at the