LevelOne FCS-5061 Manual - Page 63

Triggered Action Multi-option, Enable Alarm Output, Record stream to SD Card

Page 63 highlights

Triggered Action (Multi-option) The Administrator can specify alarm actions that will take when tampering is detected. All options are listed as follows: Enable Alarm Output Check the item and select the predefined type of alarm output to enable alarm output when tampering is detected. Record stream to SD Card Select this item and the Tampering Alarm recording will be stored in Micro SD/ SDHC card when tampering is detected. Pre-trigger buffer recording function allows users to check what happened to cause the trigger. The pre-trigger buffer time range is from 1 to 3 seconds. Select to set the recording duration after tampering occurs. The setting range is from 1 to 99999 seconds. Select to record the triggered video until the trigger is off. NOTE: Please make sure the local recording (with Micro SD/ SDHC card) is activated so that this function can be implemented. Refer to Recording for further details. Send Message by FTP/E-Mail The Administrator can select whether to send an alarm message by FTP and/or E-Mail when tampering is detected. Upload Image by FTP Select this item and the Administrator can assign a FTP site and configure various parameters. When tampering is detected, event images will be uploaded to the appointed FTP site. function allows users to check what happened to cause the trigger. The frame rate could be predetermined. On the other hand, is for users to upload certain amount of images after tampering is triggered. Check the box to upload the triggered images during certain time or keep uploading until the trigger is off. Select and enter the duration in the blank. The images of the duration will be uploaded to FTP when tampering is triggered. The setting range is from 1 to 9999 seconds. Select to make the images keep being upload to FTP during the trigger active until the tampering stops. Set the Image frequency as the upload frame rate. The setting range is from 1 frame to 15 frames. 59

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106

59
The Administrator can specify alarm actions that will take when tampering is
detected. All options are listed as follows:
Triggered Action (Multi-option)
Enable Alarm Output
Check the item and select the predefined type of alarm output to enable
alarm output when tampering is detected.
Record stream to SD Card
Select this item and the Tampering Alarm recording will be stored in Micro
SD/ SDHC card when tampering is detected.
Pre-trigger buffer recording function allows users to check what happened
to cause the trigger. The pre-trigger buffer time range is from 1 to 3
seconds.
Select <Upload for __ sec> to set the recording duration after tampering
occurs. The setting range is from 1 to 99999 seconds.
Select <Upload during the trigger active> to record the triggered video
until the trigger is off.
NOTE:
Please make sure the local recording (with Micro SD/
SDHC card) is activated so that this function can be
implemented. Refer to Recording for further details.
Send Message by FTP/E-Mail
The Administrator can select whether to send an alarm message by FTP
and/or E-Mail when tampering is detected.
Upload Image by FTP
Select this item and the Administrator can assign a FTP site and configure
various parameters. When tampering is detected, event images will be
uploaded to the appointed FTP site.
<Pre-trigger buffer> function allows users to check what happened to
cause the trigger. The <Pre-trigger buffer> frame rate could be pre-
determined.
On the other hand, <Post-trigger buffer> is for users to upload certain
amount of images after tampering is triggered.
Check the box <Continue image upload> to upload the triggered images
during certain time or keep uploading until the trigger is off. Select
<Upload for __sec> and enter the duration in the blank. The images of the
duration will be uploaded to FTP when tampering is triggered. The setting
range is from 1 to 9999 seconds. Select <Upload during the trigger
active> to make the images keep being upload to FTP during the trigger
active until the tampering stops. Set the Image frequency as the upload
frame rate. The setting range is from 1 frame to 15 frames.