Lexmark C540 Service Manual - Page 49
Fuser Error
View all Lexmark C540 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 49 highlights
5025-2xx, 4xx Service error messages (1xx, 9xx) (continued) Error code 109.06 Service Black Printhead 109.07 Service Black Printhead 109.08 Service Black Printhead 109.09 Service Black Printhead 109.10 Service Black Printhead 109.11 Service Black Printhead 109.12 Service Black Printhead 109.13 Service Black Printhead 122.xx Service Fuser Error 122.01 Service Fuser Error 122.02 Service Fuser Error 122.03 Service Fuser Error 122.04 Service Fuser Error 122.05 Service Fuser Error 122.06 Service Fuser Error 122.11 Service Fuser Error 122.12 Service Fuser Error 122.13 Service Fuser Error 122.14 Service Fuser Error Description Action The black printhead thermistor is open. Perform a POR. If the problem persists, go to "Printhead service check" on page 2-51. The black printhead thermistor is shorted to ground. Perform a POR. If the problem persists, go to "Printhead service check" on page 2-51. The black laser showed bad in testing. Perform a POR. If the problem persists, go to "Printhead service check" on page 2-51. SOS/EOS measurement did not complete. Perform a POR. If the problem persists, go to "Printhead service check" on page 2-51. Bad SOS/EOS measurement. Perform a POR. If the problem persists, go to "Printhead service check" on page 2-51. Failure writing data tot he printhead. Perform a POR. If the problem persists, go to "Printhead service check" on page 2-51. Failure reading data from the printhead. Perform a POR. If the problem persists, go to "Printhead service check" on page 2-51. Printhead declared error. Perform a POR. If the problem persists, go to "Printhead service check" on page 2-51. Fuser error Go to "Fuser service check" on page 2-32. Attempting to print with estimated power at or below minimum power. Go to "Fuser service check" on page 2-32. Fuser over temperature. Go to "Fuser service check" on page 2-32. Fuser open thermistor check failed. Go to "Fuser service check" on page 2-32. Fuser reached start temperature too quickly. Go to "122.xx-Fuser temperature incorrect" on page 2-24. Fuser failed to reach final temperature Go to "122.xx-Fuser temperature in time. incorrect" on page 2-24. Estimated power is at or below minimum power. Go to "122.xx-Fuser temperature incorrect" on page 2-24. Fuser under temperature error while in Go to "Fuser service check" on standby. page 2-32. Fuser under temperature error while printing. Go to "Fuser service check" on page 2-32. Fuser open thermistor check failed for Go to "Fuser service check" on second thermistor. page 2-32. Fuser shorted thermistor check failed Go to "Fuser service check" on for hot roll thermistor. page 2-32. Diagnostic information 2-15