LiftMaster Icon 26 ICON26 Manual - Page 19
RS485 WIRING CONFIGURATIONS, Daisy Chain
View all LiftMaster Icon 26 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
RS485 WIRING CONFIGURATIONS Configuration #1 "Daisy Chain" wiring configuration (Recommended method for superior data transmission) • Up to 31 RS485 devices supported • Maximum distance from the last RS485 device to the Telephone Entry System is 4000 Ft. • Turn "ON" the terminator switch ONLY for the last device installed in the RS485 line. • Use 22 AWG twisted pair shielded wire Turn Terminator Switch "ON" for Last Device on Wire Run Gnd + - 4000 Ft Max. Each RS485 device must have a unique "Device ID Number" set by using the rotary switches on the device. (Refer to specific RS485 Instruction sheets). Configuration #2 "Star" wiring configuration • Maximum number of wire runs allowed is 7 • Maximum distance from the last RS485 device (per wire run) to the Telephone Entry Syetem is 4000 Ft. Turn Terminator Switch "ON" for Last Device on Wire Run • Maximum number of RS485 devices present on ALL wire runs is 31. • Use 22 AWG twisted pair shielded wire 4000 Ft Max. Turn Terminator Switch "ON" for Last Device on Wire Run - + Gnd Wire Run Turn Terminator Switch "ON" for Last Device on Wire Run Turn Terminator Switch "ON" for Last Device on Wire Run Turn Terminator Switch "ON" for Last Device on Wire Run Turn Terminator Switch "ON" for Last Device on Wire Run Turn Terminator Switch "ON" for Last Device on Wire Run Each RS485 device must have a unique "Device ID Number" set by using the rotary switches on the device. (Refer to specific RS485 Instruction sheets). Icon Page 18