LiftMaster Miracle-One MIRACLE ONE Manual - Page 17
Wiring 1 Operator To Board
View all LiftMaster Miracle-One manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
MIRACLE SURGE PROTECTION ® WIRING 1 OPERATOR TO BOARD LAKE FOREST, CALIFORNIA www.eliteaccess.com Caution: Do Not over-bend the cord from the operator. Doing this will cause the wires to eventually break. REV A Caution: Do Not use wire less than 16 gauge up to 200 Ft. BLACK WHITE RED BROWN BLUE GREEN BLACK WHITE RED BROWN BLUE GREEN BURGLAR ALARM INPUT UL SENSOR CENTER LOOP SAFETY LOOP EXIT LOOP GROUND RADIO +24 VOLT +24 VAC INPUT SINGLE OR MASTER ONLY MOTOR BRAKE LIMITS 12 3 456 Removable Terminal Connector 123456 SECOND ONLY MOTOR BRAKE LIMITS Removable Terminal Wire Connector 7 8 9 10 11 12 Caution: 13 14 15 16 17 M18ake19 su2r0e B2A1 RE22WI2R3 E 24 25 26 27 makes good contact inside removable terminal connectors. DO NOT let wire insulation interfere with connection. Black White Red Brown Blue Green Important: Install the Conduit (supplied) to secure the wire to the Miracle 1 Control Board Box. If the conduit can not be used, Install a dedicated water tight conduit for 6 wires. DO NOT run AC wire in same conduit as 6 wires! More than 20 ft run, you MUST use Shielded Wire for the blue and green lines. Shield must be grounded. 16 8 BLACK WHITE RED BROWN BLUE GREEN BLACK WHITE RED BROWN BLUE GREEN BURGLAR ALARM INPUT UL SENSOR CENTER LOOP SAFETY LOOP STRIKE INPUT GROUND RADIO +24 VOLT +24 VAC INPUT MIRACLE SURGE PROTECTION REV A ® LAKE FOREST, CALIFORNIA www.eliteaccess.com SINGLE OR MASTER ONLY MOTOR BRAKE LIMITS 12 3 456 SECOND ONLY MOTOR BRAKE LIMITS 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 Supplied Conduit