Miele K 2601 Vi Operating and Installation instructions - Page 95
Cleaning the door seal, Cleaning the ventilation gaps, Replacing the Active AirClean filters
View all Miele K 2601 Vi manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 95 highlights
Cleaning and care Cleaning the door seal Risk of damage as a result of incorrect cleaning. If you treat the door seal with oils or grease, it can become porous. Do not use any oils or grease on the door seal. The door seals should be cleaned regularly with clean water, and then wiped dry with a soft cloth. Cleaning the ventilation gaps A build-up of dust will increase the energy consumption of the appliance. The ventilation gaps should be cleaned on a regular basis with a brush or vacuum cleaner (you could use a Miele Vacuum Cleaner dusting brush, for example). Replacing the Active AirClean filters The Active AirClean filters in the refrigerator section need to be replaced approx. every 6 months. Change Active AirClean Filter will appear on the display. Confirm the message with OK. To remove the holder for the Active AirClean filters, press against the retainers on both sides of the holder from the rear and pull the holder downwards diagonally from the frame. Remove the used Active AirClean filters and place the new Active AirClean filters with the surrounding edge pointing downwards in the holder. To replace the holder, press against the retainers on both sides of the holder from the rear and clamp it into the gap on the frame from below. 95