NEC UN552S External Controls - Page 111

Auto Tile Matrix Monitors Write

Page 111 highlights

21.4 Auto Tile Matrix Monitors Write This command is used in order to write the setting of H/V Monitors. 1) The controller requests the monitor to write H/V Monitors. Header SOH-'0'-Monitor ID- '0'-'A'-'0'-'C' Message Check code STX-'C'-'A'-'0'-'3'-'0'-'5'-HM-VM-ETX BCC Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller. 'A' (41h): Message type is "Command". '0'-'C'(30h, 43h): Message length (12bytes) Delimiter CR Message STX (02h): Start of Message 'C'-'A'-'0'-'3' (43h, 41h, 30h, 33h): Auto Tile Matrix Command '0'-'5' (30h. 34h): Monitors Write HM: H MONITORS 00h - 0Ah (30h, 30h - 30h, 41h) VM: V MONITORS 00h - 0Ah (30h, 30h - 30h, 41h) ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.3 "Check code" for a BCC calculation. Delimiter CR (0Dh): End of packet 2) The monitor replies a written in result. Header Message SOH-'0'-'0'-Monitor ID- STX-'C'-'B'-'0'-'3'-'0'-'5'-ST-ETX 'B'-'0'-'A' Check code BCC Header SOH (01h): Start of Header '0' (30h): Reserved '0' (30h): Message receiver is the controller. Monitor ID: Indicate a replying Monitor ID. Ex.) When this byte is set to 'A', replying monitor's ID is '1'. 'B' (42h): Message type is "Command reply". '0'-'A'(30h, 41h): Message length (14bytes) Delimiter CR Message STX (02h): Start of Message 'C'-'B'-'0'-'3' (43h, 42h, 30h, 33h): Auto Tile Matrix reply '0'-'5' (30h, 34h): Monitors Write ST: Error Status No Error : 00h (30h, 30h) Error : 01h (30h, 31h) ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.3 "Check code" for a BCC calculation. Delimiter CR (0Dh): End of packet (111/145)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145

(111/145)
21.4 Auto Tile Matrix Monitors Write
This command is used in order to write the setting of H/V Monitors.
1) The controller requests the monitor to write H/V Monitors.
Header
Message
Check code Delimiter
SOH-'0'-Monitor ID-
'0'-'A'-'0'-'C'
STX-'C'-'A'-'0'-'3'-'0'-'5'-HM-VM-ETX BCC
CR
Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'C'(30h, 43h): Message length (12bytes)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'3' (43h, 41h, 30h, 33h): Auto Tile Matrix Command
'0'-'5' (30h. 34h): Monitors Write
HM: H MONITORS
00h
0Ah (30h, 30h
30h, 41h)
VM: V MONITORS
00h
0Ah (30h, 30h
30h, 41h)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3
Check code
for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies a written in result.
Header
Message
Check code Delimiter
SOH-'0'-'0'-Monitor ID-
'B'-'0'-'A'
STX-'C'-'B'-'0'-'3'-'0'-'5'-ST-ETX
BCC
CR
Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to
A
, replying monitor
s ID is
1
.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h, 41h): Message length (14bytes)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'3' (43h, 42h, 30h, 33h): Auto Tile Matrix reply
'0'-'5' (30h, 34h): Monitors Write
ST: Error Status
No Error : 00h (30h, 30h)
Error
: 01h (30h, 31h)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3
Check code
for a BCC calculation.
Delimiter
CR (0Dh): End of packet